Appendix: Installation
8
2. INSTALLATION LOCATION
2.1 Indoor unit
2.2 Outdoor unit
!
!
WARNING
WARNING
Maintain the required space
around the appliance to
prevent overheat.
The location for installation of the appliance should not
be in an area with the following:
Direct sunlight
Heat resource
Inflammable gas
Thick oil fog
The appliance should be installed in an area,
Where the inside space can be evenly conditioned, or
Which is strong enough for the appliance, or,
Having the shortest distance for the copper tubes and
water drain hose, and
Having desired space around the appliance for
maintenance and ventilation.(Figure 1)
Min. 5cm
Min. 5cm
Min. 5cm
Figure 1
Tube arrangement
L H Added Refrigerant Provided Tube(M)
(g/m)
10
7
20
4
L: Maximum length of the tube connecting the indoor unit
and the outdoor unit.
H: The height difference between the indoor unit and the
outdoor unit.
Tube length(L)
Height difference(H)
Indoor unit
Outdoor
unit
* If the length of the tube is exceed 7m, an additional
20g/m of refrigerant should be added per 1m.
Figure 2
The indoor unit should not be
installed below a height of 1.8m.
The outdoor unit should be installed away from the
following:
Heat source and fan exhausting (Figure 3);
Director sunlight;
Figure 3
The outdoor unit should be installed in an area with,
Cool temperature;
Good ventilation;
Desired space for air inlet, outlet and maintenance
(Figure 4)
2m
2m
Air inlet
Min. 10cm
Min. 10cm
Min. 40cm
Min.10cm
Air inlet
Ground
Valve side
Min. 25cm
Top obstacle
Air outlet
Ai
r
ou
tl
et
Ob
st
ac
le
Figure 4
2
Strong base (10x10cm concrete or alike). The appliance
should be placed not less than 10cm high (Figure 5).
Fix the base with firm bolts to reduce vibration and noise.
22
Concrete or alike
Firm bolts(4)
Min. 10cm
Abo t
10cm
u
bo
40
A
ut
cm
Figure 5