![Hirschmann PowerMICE MB-2T Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/hirschmann/powermice-mb-2t/powermice-mb-2t_user-manual_2138115029.webp)
PowerMICE
Release 01 04/2014
29
Note:
The RPS60/48V EEC power supply unit does not fulfill the
requirements according to Germanischer Lloyd, criterion EMC1, relating to
conducted emissions on the 230 V AC side. If this requirement must be
fulfilled, connect a corresponding power supply unit that fulfills both this
requirement
and
the basic requirements.
Connect the PoE voltage to the 3-pin terminal block included in the scope
of delivery, as shown in the following diagram.
Make sure the following requirements are met:
Supply line length < 3 m.
Supply line cross section is suitable for 1.5 A.
Mount the terminal block for the PoE supply voltage on the bottom of the
PoE module using the snap lock. Make sure it latches securely in place.
Note:
Use 4-pair twisted pair cables to connect the terminal devices. Only
connect terminal devices that conform to IEEE 802.3af.
Figure
Pin
Assignment
1
+ 48 V
2
—
3
0 V
Table 4:
Pin assignment of the 3-pin terminal block