Страница 1: ...PowerMICE Document No 039654005 Release 01 04 2014 Technical support https hirschmann support belden eu com User Manual Installation Industrial Ethernet Switch PowerMICE...

Страница 2: ...ures described here are binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the best of the com...

Страница 3: ...nstalling the SFP modules 26 2 2 5 Adjusting DIP switch settings on basic module 27 2 2 6 Adjusting the DIP switch settings on the MM20 A8A89999SAHH media module 28 2 2 7 Connecting the MM22 T1T1T1T1...

Страница 4: ...4 PowerMICE Release 01 04 2014...

Страница 5: ...dicates that an electrical hazard exists which will result in personal injury if the instructions are not followed This is the safety alert symbol It is used to alert you to potential personal injury...

Страница 6: ...C EN 60950 1 The supply voltage is electrically isolated from the housing Note Only the PoE media module MM22 T1T1T1T1 has an external power supply Use undamaged parts Relevant for North America The d...

Страница 7: ...connection in an explosive atmosphere could result in an explosion Power Supply range P1 P2 redundant 18 32 VDC 4 5 2 5 A Relay contacts The relays are Sealed Devices THE RELAY TERMINALS ARE DEPENDENT...

Страница 8: ...nces of more than 119 V When the temperature under rated conditions exceeds 70 C at the cable or conduit entry point or 80 C at the branching point of the conductors the temperature specification of t...

Страница 9: ...ever insert any pointed objects small screwdrivers wires etc into the product Never insert sharp objects small screwdrivers wires etc into the connection terminals for the supply voltage or the signal...

Страница 10: ...m 1 97 in from the device and relative air humidity specified in the technical data Install the device in a location where the climatic threshold values specified in the technical data will be observe...

Страница 11: ...D or LASER components in compliance with IEC 60825 1 2007 CLASS 1 LASER PRODUCT CLASS 1 LED PRODUCT Note Follow the safety instructions for the media modules You will find these instructions in the De...

Страница 12: ...ce must accept any interference received including interference that may cause undesired operation Appropriate testing has established that this device fulfills the requirements of a class A digital d...

Страница 13: ...er manual Router Configuration user manual Graphical User Interface reference manual Command Line Interface user manual The Industrial HiVision Network Management Software provides you with additional...

Страница 14: ...tions and also provide long term reliability and flexibility The devices work without a fan The voltage is supplied redundantly The following installation options are available simply snapping them on...

Страница 15: ...ny network Figure 1 Basic module with media modules attached 1 Slots for one 10 100 Mbit s media module 2 Basic module 3 Slot for the Gigabit media module 1 1 Description of the modules The industrial...

Страница 16: ...lots for 10 100 Mbit s media modules 1 slot for 1 Gbit s media modules With the expansion module you add 2 more slots for 10 100 Mbit s media modules With its 4 port media modules the basic module all...

Страница 17: ...lot for media modules MM2 or MM3 with 2 to 4 ports each 4 Ground screw 5 Connections on the bottom of the basic module 6 Button for setting the display status 7 LEDs for device status and display stat...

Страница 18: ...module They differ with regard to the number of interfaces and the media type The different interfaces of the media modules provide you with the following interface specific functions Specific functi...

Страница 19: ...ation of the port numbers 6 Bottom side of the device MM2 media modules Module type TP ports 10 100 Mbit s F O port multi mode 10 Mbit s F O port multi mode 100 Mbit s F O port single mode 1300 nm 100...

Страница 20: ...Mbit s F O port multi mode 100 Mbit s F O port single mode 1300 nm 100 Mbit s F O port single mode 1550 nm 100 Mbit s MM3 4TX5 4 M12 MM3 4FLM4 4 ST MM3 1FXM2 3TX1 3 RJ45 1 DSC MM3 2FXM2 2TX1 EEC 2 RJ...

Страница 21: ...the individual ports are not electrically insulated from each other The following conditions are met in accordance with IEEE 802 3af Endpoint PSE Alternative B MM4 media modules The 4 port MM4 4TX SF...

Страница 22: ...rt 1 2 Port 2 SFP slot can be used as alternative to port 2 3 Port 3 SFP slot can be used as alternative to port 3 4 Port 4 SFP slot can be used as alternative to port 4 5 Representation of port numbe...

Страница 23: ...The SFP modules are plugged into the SFP slots of the Fast ETHERNET media module MM20 Z6Z6Z6Z6 or the Gigabit ETHERNET media modules MM4 4TX SFP and MM4 2TX SFP in order to have an F O port Module MM2...

Страница 24: ...ng Installing the media modules Filling out and attaching labels Installing the SFP modules Adjusting DIP switch settings on basic module Adjusting the DIP switch settings on the MM20 A8A89999SAHH med...

Страница 25: ...ule first remove the protective cap on the plug Plug the media module onto the plug Fasten the 4 screws at the corners of the media module Fit the media modules in sequence from left to right Check wh...

Страница 26: ...he basic module MAC address of the device 6 Labeling the basic module name of the module Attach the labels included in the delivery to the basic module and the media modules as required 2 2 4 Installi...

Страница 27: ...are taken over after the restart In the ON position ports 1 and 2 in module 2 form the connection for the HIPER Ring OFF position ports 1 and 2 in module 1 form the connection for the HIPER Ring Stan...

Страница 28: ...equirements 2 2 7 Connecting the MM22 T1T1T1T1 PoE media module The MM22 T1T1T1T1 PoE media module with PoE voltage 48 V DC safety extra low voltage is supplied with power via an external power supply...

Страница 29: ...o the 3 pin terminal block included in the scope of delivery as shown in the following diagram Make sure the following requirements are met Supply line length 3 m Supply line cross section is suitable...

Страница 30: ...contact monitors proper functioning of the device thus enabling remote diagnostics You can specify the type of function monitoring in the Management You can also use the switch Web page to switch the...

Страница 31: ...locks Make sure the snap lock latches securely in place By connecting the voltage supply via the terminal blocks you start the operation of the device 2 2 10 Installing the device on the DIN rail grou...

Страница 32: ...10BASE T 100BASE TX standard These ports support Autonegotiation Autopolarity Autocrossing if autonegotiation is activated 100 Mbit s half duplex mode 100 Mbit s full duplex mode 10 Mbit s half duple...

Страница 33: ...tion These connections are RJ45 sockets 10 100 1000 Mbit s TP ports enable the connection of terminal devices or independent network segments according to the IEEE 802 3 10BASE T 100BASE TX 1000BASE T...

Страница 34: ...ependent network segments according to the IEEE 802 3 1000BASE SX 1000BASE LX standard These ports support Autonegotiation Full duplex mode Delivery state autonegotiation activated Note Make sure that...

Страница 35: ...12 Installing the MB 2T expansion module The MB 2T expansion module enables you to add 2 slots for media modules to the basic module You can install the expansion module while the device is operating...

Страница 36: ...the basic module show the current meaning of the port LEDs of the media modules Figure 15 SELECT button on the basic module 1 SELECT button 2 Display LEDs 2 3 Display elements After establishing the...

Страница 37: ...hing green Incorrect configuration of the HIPER Ring e g the ring is not connected to the ring port RUN BOOT RUN green LED Glowing green System is ready for operation Flashing green System is booting...

Страница 38: ...speed AUTONEG Autonegotiation green LED Glowing green The port LEDs of the media modules display the port configuration type RING PORT Ring port green LED Glowing green The port LEDs of the media modu...

Страница 39: ...wing green Autonegotiation is active 1 to 4 RING PORT green yellow LED Glowing green This port is assigned to the HIPER Ring 1 to 4 STAND BY green yellow LED Glowing green Connection port for the data...

Страница 40: ...The device looks for the IP address using DHCP Password for management Login user password public read only Login admin password private read and write V 24 data rate 9 600 Baud Ring redundancy deact...

Страница 41: ...ally connected to the front panel of the device The V 24 interface is not electrically isolated from the supply voltage Figure 17 Pin assignment of the V 24 interface and the DB9 connector Note You wi...

Страница 42: ...frequency of the switching operations Check the resistance of the closed relay contacts and the switching function depending on the frequency of the switching operations Hirschmann is continually work...

Страница 43: ...e device from the hat rail press the device downwards and pull it out from under the hat rail Figure 18 Disassembly Disassembling the SFP modules Pull the module out of the socket by means of the open...

Страница 44: ...on voltage to 45 V DC 1 mA Signal contact Switching current max 1 A SELV Switching voltage max 60 V DC or max 30 V AC SELV Environment Storage temperature Ambient air 40 C to 70 C Humidity 10 to 95 no...

Страница 45: ...PowerMICE Release 01 04 2014 45 Dimension drawing 316 8 133 56 4 135 65 41 34 84 24 20 08...

Страница 46: ...e line line Power line line earth Data line 1 kV 2 kV 2 kV IEC EN 61000 4 6 Line conducted interference voltages 150 kHz 80 MHz 10 V EN 61000 4 9 Impulse shaped magnetic fields 300 A m EMC emitted int...

Страница 47: ...125 m 0 10 5 dB 0 550 m 1 0 dB km 500 MHz km LX LC SM 1310 nm 9 125 m 0 10 5 dB 0 20 kme e including 2 5 dB system reserve when compliance with the fiber data is observed 0 4 dB km 3 5 ps nm km LX LC...

Страница 48: ...thernet Transceiver Product code Wave length Fiber System attenua tion Example for F O line length a a including 3 dB system reserve when compliance with the fiber data is observed Fiber attenuation B...

Страница 49: ...ower consumpti on Power output Operating temperature ambient air temperature Order number MS4128 L2P 16 0 W 54 7 Btu IT h 0 C to 60 C 943 009 102 MS4128 L3E 16 0 W 54 7 Btu IT h 0 C to 60 C 943 009 20...

Страница 50: ...Btu IT h 0 C to 60 C 943 835 101 MM3 1FXS2 3TX1 2 2 W 7 5 Btu IT h 0 C to 60 C 943 838 101 MM3 2FXS2 2TX1 3 4 W 11 6 Btu IT h 0 C to 60 C 943 762 101 MM3 4FXS2 7 0 W 23 9 Btu IT h 0 C to 60 C 943 836...

Страница 51: ...Product code MM30 O7O7O7O7SA media module 1000 Mbit s with four Gigabit Ethernet combo ports four SFP ports or alternatively TP ports RJ45 This example corresponds to the MM4 4TX SFP module with the...

Страница 52: ...bit s G2 Single mode Long Haul FX DSC 200km only 100 Mbit s F4 Multi mode FL ST 10 Mbit s P9 POF FX SCRJ 100 Mbit s O7 Combo port Gigabit Ethernet SFP 1000 Mbit s A8 AUI Sub D Z6 Fiber optic SFPslot 1...

Страница 53: ...s see table under MM2 media modules on page 19 MM3 media modules see table under MM3 media modules on page 20 MM4 media modules see table under MM4 media modules on page 21 Device Scope of delivery Po...

Страница 54: ...le LH LC EEC type A B 943 975 101 Fast Ethernet SFP transceiver Order number M FAST SFP MM LC 943 865 001 M FAST SFP MM LC EEC 943 945 001 M FAST SFP SM LC 943 866 001 M FAST SFP SM LC EEC 943 946 001...

Страница 55: ...quipment radio interference characteristics EN 61131 2 Programmable logic controllers EN 50121 4 Railway applications EMC emitted interference and interference immunity for signal and telecommunicatio...