6
Installation Octopus II
Release 06 10/2018
Certified usage
Use the product only for the application cases described in the
Hirschmann product information, including this manual.
Operate the product only according to the technical specifications.
See “Technical data” on page 49.
Connect to the product only components suitable for the requirements
of the specific application case.
Requirements for connecting electrical wires
Before connecting the electrical wires,
always
verify that the
requirements listed are complied with.
Requirements for connecting the signal contact
Before connecting the signal contact,
always
verify that the requirements
listed are complied with.
Requirements for connecting the grounding
Before connecting the grounding,
always
verify that the requirements
listed are complied with.
All of the following requirements are complied with:
The electrical wires are voltage-free.
The cables used are permitted for the temperature range of the application case.
Table 1:
Requirements for connecting electrical wires
All of the following requirements are complied with:
The voltage connected complies with the requirements for a safety extra-low voltage
(SELV) as per IEC/EN 60950-1.
The connected voltage is limited by a current limitation device or a fuse.
Observe the electrical threshold values for the signal contact.
See “General technical data” on page 49.
Table 2:
Requirements for connecting the signal contact
Device variant
Requirements
Only for device variants
featuring supply voltage with
characteristic value M9:
The wire diameter of the ground conductor in the power supply
cable is the same size as or bigger than the wire diameter of the
power supply cables, however of at least 0.75 mm² (AWG18).
All variants
The wire diameter of the ground conductor is at least 1.5 mm² at
the device casing. When connecting the provided cable lug, use
a professional crimping tool specified for the wire size. Follow the
instructions of the crimping tool. The pull out force of the crimped
connection is at least 135 N according to the technical standard
IEC 60352-2.
Table 3:
Requirements for connecting the grounding
Содержание Octopus II