![Hirschmann Octopus II Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/hirschmann/octopus-ii/octopus-ii_user-manual_2138111038.webp)
38
Installation Octopus II
Release 06 10/2018
2.4.2
Supply voltage with the characteristic value FF
A 5-pin 7/8" plug is available for the redundant supply to the device.
You find the prescribed tightening torque in chapter:
See “Technical data” on page 49.
The supply voltage is connected to the device casing through protective
elements exclusively.
You have the option of supplying the supply voltage redundantly, without
load distribution.
With a non-redundant supply of the supply voltage, the device reports the
loss of a supply voltage. You can prevent this message by changing the
configuration in the Management.
Connect the electrical wires to the socket according to the pin
assignment.
2.4.3
Supply voltage with the characteristic value HH
A 5-pin M12 plug is available for the redundant supply to the device.
You find the prescribed tightening torque in chapter:
See “Technical data” on page 49.
The supply voltage is connected to the device casing through protective
elements exclusively.
You have the option of supplying the supply voltage redundantly, without
load distribution.
With a non-redundant supply of the supply voltage, the device reports the
loss of a supply voltage. You can prevent this message by changing the
configuration in the Management.
Type and specification of the
supply voltage
Pin assignment
Rated voltage range
24 V DC ... 48 V DC
P1+
Plus terminal of supply
voltage 1
Voltage range incl. maximum
tolerances
16.8 V DC ... 60 V DC
P1
−
Minus terminal of supply
voltage 1
N.C.
—
P2
−
Minus terminal of supply
voltage 2
P2+
Plus terminal of supply
voltage 2
P2−
P2+
P1+
P1−
N.C.