GL Guidelines
AC and DC supply connections
—
EMC 1
—
—
FCC 47 CFR Part 15
AC and DC supply connections
Class A
Class A
Class A
Class A
EN 61000-6-4
AC and DC supply connections
Fulfilled
Fulfilled
Fulfilled
Fulfilled
EN 55032
Telecommunication connections
Class A
Class A
Class A
Class A
EN 61000-6-4
Telecommunication connections
Fulfilled
Fulfilled
Fulfilled
Fulfilled
EMC interference
immunity
Standard
applications
Navy
applications
Railway applica-
tions (trackside)
Substation
applications
Electrostatic discharge
EN 61000-4-2
IEEE C37.90.3
Contact discharge
± 4 kV
± 6 kV
± 6 kV
± 8 kV
EN 61000-4-2
IEEE C37.90.3
Air discharge
± 8 kV
± 8 kV
± 8 kV
± 15 kV
Electromagnetic field
EN 61000-4-3
80 MHz ... 3000 MHz
10 V/m
10 V/m
20 V/m
10 V/m
IEEE 1613
80 MHz ... 1000 MHz
—
—
—
35 V/m
Fast transients (burst)
EN 61000-4-4
IEEE C37.90.1
AC/DC supply connection
± 2 kV
± 2 kV
± 2 kV
± 4 kV
EN 61000-4-4
IEEE C37.90.1
Data line
± 4 kV
± 4 kV
± 4 kV
± 4 kV
Voltage surges - DC supply connection
EN 61000-4-5
line/ground
± 2 kV
± 2 kV
± 2 kV
± 2 kV
IEEE 1613
line/ground
—
—
—
± 5 kV
EN 61000-4-5
line/line
± 1 kV
± 1 kV
± 1 kV
± 1 kV
Voltage surges - data line
EN 61000-4-5
line/ground
± 1 kV
± 1 kV
± 2 kV
± 4 kV
Conducted disturbances
EMC interference
emission
Standard
applications
Navy a
pplications
Railway applica-
tions (trackside)
Substation
applications