14
Installation EAGLE One
Release 06 12/2018
Use of EAGLEONE and TOFINOXE series devices
according to the European directive 2014/34/EU
For
Use in explosive atmospher
es according to the Eur
opean dir
ective 2014/34/EU:
Applied Standards:
The Use in Hazardous Locations with explosive atmospher
es is only allowed for
EAGLEONE or
TOFINOXE model No´s. which are labeled accordingly - including “
([
II 3 G”,
“Ex nA
IIC
T4 Gc” “DEKRA
13ATEX0184X”.
EN60079-0, 2012
EN60079-15, 2010
SPECIAL
CONDITIONS FOR SAFE USE:
The modules shall be installed in a suitable enclosur
e pr
oviding a degr
ee of pr
otection of at
least IP54 according to EN 60529, taking into account the envir
omental conditions under
which the equipment will be used.
Pr
ovisions shall be made to pr
event the rated voltage fr
om being exceeded by transient
disturbances of mor
e than 1
19
V
.
When the temperatur
e under
rated conditions exceeds 70 °C at the cable or
conduit entry
SRLQWRU
&DWWKHEUDQFKLQJSRLQWRIWKHFRQGXFWRUVWKHW
HPSHUDWXU
HVSHFL¿FDWLRQRIWKH
selected cable shall be in compliance with the actual measur
ed temperatur
e values.
Manufactured in 72654 Neckartenzlingen / Germany by Hirschmann Automation and
Control GmbH.
DOM: ww/yy (Date of manufactur w - week, y - year. Refer to the device label).