background image

System 2000 AUTO TEMP

1

System 2000 Auto Temp

1. Specifications

Model:

ACT-12 -- Staged on/off controller with 7 temperature inputs and 13 relay outputs

Electrical Ratings

Voltage Input -- 120 VAC (240VAC available) 50/60 Hz.
Power Consumption -- 20 VA Max.

Contact Ratings:

1/10 HP Inductive @ 120VAC
2 Amp @ 12VAC Resistive

Sensors:

Negative Temperature Coefficient Thermistor type. Maximum 1000 ft distance from sensor to controller.
Software calibration capability in controller.

Temperature Range:

-20.0F to 120.0F all targets settable in same range in 1F increments.

2. Limited Warranty

All products are warranted to be free from defects in material and workmanship for a
period of one year from the date of purchase if installed and used in strict accordance with
the installation instructions. Liability is limited to the sale price of any products proved to
be defective or, at manufacturers option, to the replacement of such products upon their
return. No products are to be returned to the manufacturer, until there is an inspection
and/or a return-goods authorization (RGA) number is issued.
All complaints should be directed first to the authorized distributor who sold the product.
If satisfaction is not obtained or the name of the distributor is not known, write the
manufacturer that appears below, directed to the attention of Customer Service Manager.
This limited warranty is expressly in lieu of any and all representations and warranties
expressed or implied, including any implied warranty of merchantability or fitness for a
particular purpose. The remedy set forth in this limited warranty shall be the exclusive
remedy available to any person. No person has authority to bind the manufacturer to any
representation or warranty other than this limited warranty. The manufacturer shall not be
liable for any consequential damages resulting from the use of our products or caused by
any defect, failure or malfunction of our products. (Some areas do not allow the exclusion
or limitation of incidental or consequential damages, so the above limitation or exclusion
may not apply to you.)
This warranty gives you specific legal rights and you may also have other rights that vary
from area to area.

Warrantor:

Hired-Hand, Inc.
1733 Co. Rd. 68
PO Box 99
Bremen, AL  35033

Содержание System 2000 AUTO TEMP

Страница 1: ...4801 1001 Rev 9 96 System 2000 AUTO TEMP 12 Stage Temperature Controller Hired Hand Inc 1733 Co Rd 68 PO Box 99 Bremen AL 35033 ...

Страница 2: ...___________________________________________4 5 1 2 Target Temp_________________________________________________________________4 5 1 3 Timer Runtime Percentage______________________________________________________4 5 1 4 Special Functions _____________________________________________________________4 5 2 The Program Features ____________________________________________________ 5 5 2 1 Flock Calcul...

Страница 3: ...r a return goods authorization RGA number is issued All complaints should be directed first to the authorized distributor who sold the product If satisfaction is not obtained or the name of the distributor is not known write the manufacturer that appears below directed to the attention of Customer Service Manager This limited warranty is expressly in lieu of any and all representations and warrant...

Страница 4: ...n of temperature sensors to operate The controller operates off a single temperature set point which is manipulated via the two buttons labeled Target Temp The run time percentage of each room s timer is settable via the two buttons labeled Runtime Percent The status of the 12 stages is displayed on the face A glance at the facepad will confirm whether a stage is on whether it is heat or cool whet...

Страница 5: ... at 2 degrees The System will engage the fans when building temperature reaches 87 degrees Target Temp Offset Differential Cool Mode On 80 5 2 87 If the Target Temp is set at 80 degrees Offset set at 5 degrees and Differential set at 2 degrees The System will disengage the fans when building temperature reaches 85 degrees Target Temp Offset Cool Mode Off 80 5 85 6 Programming the System Programmin...

Страница 6: ...ich can be used to describe the function of a particular stage A section of the System Program Guide can be cut out and installed in this slot 6 1 2 Target Temp The target temp is the temperature that the system is attempting to maintain The default display shows the current system target temperature under tt If you wish to change the target temperature in a given room wait until that room number ...

Страница 7: ...sired programming feature is displayed These program features are arranged in a loop you can move forward up or backward down through the loop with the Select keys In moving backward down through the loop you move from one basic program to the next To make program changes other than yes to run the program or no to skip it you must move forward up through the loop Once selected the change setting k...

Страница 8: ... required is the number of rooms Use the Change Setting arrows to select a number from one to four 6 2 2 2 Sensors for Display The second entry required is the Sensors for Display which is important in 2 different ways First of all the sensors selected here are used to generate the default temperature which is displayed by the controller The second and perhaps most important use of Sensors for Dis...

Страница 9: ...e utilizing an offset differential method See Offset and Differential earlier in this manual Each cool stage can be placed on the system timer This is a programmable timer which may have a period of from 1 to 15 minutes and any percentage from 1 to 100 percent The stages are programmed in the Program Features section of the controller 6 2 4 Setting the System Clock The system clock is a battery ba...

Страница 10: ...ontroller labeled Artificial Light in and out An external relay or contactor must be used to control the lighting as the relay in the Auto Temp is not heavy enough When programming this feature the operator is prompted for Number of Cycles up to two Time on and Time off The operator can use up to two different light cycles in every day 6 2 8 Feed Control This feature can be used for feeders or any...

Отзывы: