background image

System 2000 AUTO TEMP

6

have counted. When you have entered the right number, press the Select
Features up arrow key to move to the next screen.

6.2.1.4.

 

Data View

This part of the program will show you the day of the growout, number of birds
your flock contained originally, average daily mortality, and number of birds
that remain in your flock on this day in the growout.

6.2.1.5.

 

Reset Flock Info

Selecting yes with the Change Setting up arrow clears all settings you have
entered in the Flock information section. Because it clears all information, you
need to only do this at the beginning of each growout.

6.2.2.

 

Programming the Rooms

The auto Temp can control up to 4 different rooms with each room having its own
sensors, ramp, target temperature, and timer. The rooms are programmed under the
Program Feature called Program Rooms. The items programmed under this heading are:
Number of rooms, which Sensor is in which room, Temperature Ramp for each room,
and the Timer Period for each room. Each of these is discussed below:

6.2.2.1.

 

Number of Rooms

The first entry required is the number of rooms. Use the Change
Setting arrows to select a number from one to four.

6.2.2.2.

 

Sensors for Display

The second entry required is the Sensors for Display which is
important in 2 different ways. First of all the sensors selected here are
used to generate the default temperature which is displayed by the
controller. The second and perhaps most important use of Sensors for
Display is the fact that this composite temperature as compared to the
Target Temperature determines whether the controller is in heat mode,
or cool mode for that particular room. (Remember that no heat stage
may run while a cool stage is running.) Use as many sensors as
possible in each room.

When programming Sensors For Display, the system prompts as
follows:

Pick sensors to display
Use stages 1-7 Room 1

When displaying this prompt, the controller "bubbles" the lights on
stages 1-7 and then displays 1 or more lights continuously. At this
point, the stage 1 light represents sensor 1, Stage 2 light is sensor 2,
and so on. If you wish to use an average of sensors 1,2, and 3 for this
particular room, simply push the buttons for stages 1, 2, and 3 until
those 3 are lighted. You will be prompted for sensors for Display for
each of the Rooms selected in 

"Number of Rooms"

.

Содержание System 2000 AUTO TEMP

Страница 1: ...4801 1001 Rev 9 96 System 2000 AUTO TEMP 12 Stage Temperature Controller Hired Hand Inc 1733 Co Rd 68 PO Box 99 Bremen AL 35033 ...

Страница 2: ...___________________________________________4 5 1 2 Target Temp_________________________________________________________________4 5 1 3 Timer Runtime Percentage______________________________________________________4 5 1 4 Special Functions _____________________________________________________________4 5 2 The Program Features ____________________________________________________ 5 5 2 1 Flock Calcul...

Страница 3: ...r a return goods authorization RGA number is issued All complaints should be directed first to the authorized distributor who sold the product If satisfaction is not obtained or the name of the distributor is not known write the manufacturer that appears below directed to the attention of Customer Service Manager This limited warranty is expressly in lieu of any and all representations and warrant...

Страница 4: ...n of temperature sensors to operate The controller operates off a single temperature set point which is manipulated via the two buttons labeled Target Temp The run time percentage of each room s timer is settable via the two buttons labeled Runtime Percent The status of the 12 stages is displayed on the face A glance at the facepad will confirm whether a stage is on whether it is heat or cool whet...

Страница 5: ... at 2 degrees The System will engage the fans when building temperature reaches 87 degrees Target Temp Offset Differential Cool Mode On 80 5 2 87 If the Target Temp is set at 80 degrees Offset set at 5 degrees and Differential set at 2 degrees The System will disengage the fans when building temperature reaches 85 degrees Target Temp Offset Cool Mode Off 80 5 85 6 Programming the System Programmin...

Страница 6: ...ich can be used to describe the function of a particular stage A section of the System Program Guide can be cut out and installed in this slot 6 1 2 Target Temp The target temp is the temperature that the system is attempting to maintain The default display shows the current system target temperature under tt If you wish to change the target temperature in a given room wait until that room number ...

Страница 7: ...sired programming feature is displayed These program features are arranged in a loop you can move forward up or backward down through the loop with the Select keys In moving backward down through the loop you move from one basic program to the next To make program changes other than yes to run the program or no to skip it you must move forward up through the loop Once selected the change setting k...

Страница 8: ... required is the number of rooms Use the Change Setting arrows to select a number from one to four 6 2 2 2 Sensors for Display The second entry required is the Sensors for Display which is important in 2 different ways First of all the sensors selected here are used to generate the default temperature which is displayed by the controller The second and perhaps most important use of Sensors for Dis...

Страница 9: ...e utilizing an offset differential method See Offset and Differential earlier in this manual Each cool stage can be placed on the system timer This is a programmable timer which may have a period of from 1 to 15 minutes and any percentage from 1 to 100 percent The stages are programmed in the Program Features section of the controller 6 2 4 Setting the System Clock The system clock is a battery ba...

Страница 10: ...ontroller labeled Artificial Light in and out An external relay or contactor must be used to control the lighting as the relay in the Auto Temp is not heavy enough When programming this feature the operator is prompted for Number of Cycles up to two Time on and Time off The operator can use up to two different light cycles in every day 6 2 8 Feed Control This feature can be used for feeders or any...

Отзывы: