Integrated Control System 500
8
6.1.2.2.4.Five/Ten Minute Timer
INSTALL JUMPER FOR
5 MINUTE TIMER
The controller's internal timer is normally a ten minute timer.
However, installing a jumper on this position allows you to set the
internal timer to a five minute timer.
6.1.2.2.5.Run Time Adjust
This setting tells the controller how long to run the curtain machine
when a change is needed. If 60 seconds is selected, the controller will
run the machine for 60 seconds, or until the curtain is fully open, or
closed.
6.1.2.2.6.Cycle Time Adjust
This potentiometer is used to set the time delay between curtain
operations. If cycle time is set for 3 minutes, then the curtain will
move every 3 minutes if needed. The curtain will not move between
cycles, unless it is manually moved.