Work instructions
1) Turn on the main power switch.
2) Tighten the first screw.
The number of screws display is lowered by one.
3) After tightening the set number of screws, tightening of screws is finished.
•
The number of screws display reaches “00” and the complete buzzer sounds.
•
Afterwards, it is automatically reset and the initial setting for the number of screws to
tighten is displayed.
•
This work can be repeated.
3. Counter mode
✽
Use this mode when controlling an electric screwdriver for each piece of work and fixing
of work piece using the external device function.
✽
The total number of work pieces completed can be counted by connecting a commercially
available total counter.
■
Connections
1) Connect the connector for the screwdriver cord to the metal connector of this equip-
ment.
2) Connect the power supply cord for this device to a power supply that supplies the rated
power (AC outlet) and connect to ground.
3) Make connections for each control signal with reference to Fig. 1.
■
Setup instructions
1) Turn on the main power switch.
2) Set 00 in the System Setting Mode (F1 Display " ").
3) Set the number of screws to be tightened using the Count Setting Mode (F1 Display
" ").
4) Set the Work Set Timer operating time to suit the work piece using the WS-T Setting
Mode (F1 Display " ") switch (range from 0 second to 3.9 seconds).
5) Set the Counter Timer operating time using the CN-T Setting Mode (F1 Display " ")
switch (range of 0.01 second to 0.99 second) while performing confirmation tightening.
6) Set the Work Reset Timer operating time to suit the work piece using the WR-T Setting
Mode (F1 Display " ") switch (range from 0 second to 3.9 seconds).
7) Exit the Setting Mode by pressing the F1 switch for longer than 1 second.
8) Preparation settings are now complete.