1. Connections
1) Connect the screwdriver cord to the metal connector of the main unit.
2) Connect the unit's power supply cord to an outlet that supplies the rated power (AC
power outlet), and then connect to ground.
2. Setup instructions
1) Confirm MODE settings (factory settings)
•
Turn the main power switch on while pressing the F1 switch.
(If the unit is already switched on, press the F1 and Reset switches together, before
releasing the Reset switch only)
A buzzer (beeping sound) will sound with the F1 switch. Continue pressing the switch (for
1 second or more) until " " is shown in the F1 display.
2) Press the F1 switch until " " is shown.
•
Confirm that "00" is shown in the settings display.
3) Press the Reset switch.
3. Work instructions
1) Turn the main power switch on.
2) Settings for the Work Set Timer
•
Press the F1 and Reset switches together, before releasing the Reset switch only. A
buzzer (beeping sound) will sound with the F1 switch. Continue pressing the switch (for
1 second or more) until " " is shown in the F1 display.
•
Use the F1 switch to change to the Adjust Work Set Timer mode (F1 Display " ") and
set the timer settings with the x10, x1 switches.
(Setting range from 0.1 second to 3.9 seconds)
•
After the Work Set Timer operation has completed (time up), the valve signal will be
generated.
(The signal will continue to be generated until the unit is reset or counting is completed)
•
When settings have been completed, press the F1 switch to move to the next setting.
•
When all settings have been completed, press the F1 switch for 1 second or more. The
buzzer will sound twice, and the setting mode will close.
3) Change to Counter Timer Setting mode (F1 Display " ") and set the count timer while
performing confirmation tightening with the x10 and x1 switches.