HIOS BLOP-STC 3 Скачать руководство пользователя страница 1

Screw counter series

BLOP-STC 3 

CLT-70STC 3

Operation Manuals

(March, 2017)

1-16-5 Akiyama, Matsudo City, 
Chiba Pref., Japan
TEL: 81 (Japan) 47-392-2001
FAX: 81 (Japan) 47-392-7773

CLT-70STC 3 

BLOP-STC 3 

17A

Operation manual No. ET-A012

Utilizing 100

 post-consumer 

recycled paper pulp

HIOS Inc.

Содержание BLOP-STC 3

Страница 1: ...C 3 Operation Manuals March 2017 1 16 5 Akiyama Matsudo City Chiba Pref Japan TEL 81 Japan 47 392 2001 FAX 81 Japan 47 392 7773 CLT 70STC 3 BLOP STC 3 17A Operation manual No ET A012 Utilizing 100 pos...

Страница 2: ...cation 4 Compatible screwdriver 5 Primary functions and description of terms 5 Description of name and function for each section 7 Front panel 7 Rear panel 10 Function setting table 13 Initial setting...

Страница 3: ...ber of screws is automati cally renewed using an auto reset function and the electric screwdriver will not oper ate until the set signal for confirmation of the work piece is received Screwdriver oper...

Страница 4: ...the cause of malfunction or failure Do not connect the 24V DC terminal to any of the output terminals COMP VALVE BZ ER BZ or ground terminals on the terminal block on the rear panel This con nection w...

Страница 5: ...k If static electricity is not discharged it may cause a malfunction due to static electricity flowing from the tip of the bit Do not expose to severe shock such as dropping Do not connect other maker...

Страница 6: ...d for this equipment is a photo coupler input The maximum input current is of 10 mA When connecting an open collector connect the collector to the input terminal and the emitter to the GND terminal Ca...

Страница 7: ...ator s manual finish of screw tightening refers to normal tightening of one screw In this operator s manual completion of screw tightening refers to normal tightening work that is performed for 1 work...

Страница 8: ...s failed fit a replacement fuse Spare fuses are stored inside the AC inlet rear panel HI LOW switch switching of rotational speed HI LOW Sets the output voltage to high or low This switch changes the...

Страница 9: ...after reset Display Pressing the button for longer than 1 second while in Change Function Mode will cause a buzzer to sound shutting down the Change Function Mode Function switch F2 F3 x10 x1 Setting...

Страница 10: ...et Timer 6 System Setting Mode Display Settings for the following features are available a Controls display of remaining number of screws see page 12 ON display OFF no display b Controls buzzer sound...

Страница 11: ...l input when there is no voltage between the set terminal and the ground terminal Caution In order to prevent incorrect operation operation of the electric screwdriver is not per mitted until after th...

Страница 12: ...sed to fix work pieces in place Connect the terminal of the solenoid valve for the external device to the 24V DC terminal and the solenoid valve ground terminal to the valve terminal When an external...

Страница 13: ...until there is a reset or count down is completed When a separate power supply is used for the external device connect the devices to a common ground and use an external power supply Add a diode to t...

Страница 14: ...Function Setting Table 13...

Страница 15: ...is shown in the settings display 3 Press the Reset switch 3 Work instructions 1 Turn the main power switch on 2 Settings for the Work Set Timer Press the F1 and Reset switches together before releasi...

Страница 16: ...timer is 0 2 second When settings have been completed press the F1 switch to move to the next setting When all settings have been completed press the F1 switch for 1 second or more The buzzer will sou...

Страница 17: ...the display of remaining number of screws ON display OFF not displayed b BUZZ Controls the buzzer sound ON buzzer noise OFF no buzzer noise c RCN T Controls the reverse count ON on OFF off for BLOP ST...

Страница 18: ...is not used and only the counting function is used for performing work This mode is for cases where work pieces are not fixed and for use of a target count to prevent careless mistakes Connections 1...

Страница 19: ...is equip ment 2 Connect the power supply cord for this device to a power supply that supplies the rated power AC outlet and connect to ground 3 Make connections for each control signal with reference...

Страница 20: ...display is lowered by one 4 After tightening the set number of screws tightening of screws is finished The number of screws display changes to 00 and the work reset timer operation starts Next the wor...

Страница 21: ...the other electric screwdriver is prevented from operating The total number of work pieces completed can be counted by connecting a commercially available total counter Furthermore if they are connec...

Страница 22: ...Setting Mode by pressing the F1 switch for longer than 1 second 2 Set B using the following procedures Set 00 in the System Setting Mode F1 Display Set the number of screws to be tightened using the C...

Страница 23: ...COMP A RESET SET GND COMP RESET SET GND 24V DC VALVE BZ ER BZ 24V DC VALVE BZ ER BZ B Total counter Fig 2 Contact switch for Reset Work detection contact switch 22...

Страница 24: ...of the final screw TM 2 timing chart when loosening a screw TM 3 timing chart for tightening of the final screw TM 4 timing chart for first method of stopping operation of error buzzer TM 5 timing ch...

Страница 25: ...rews perform torque up procedure 13 End of electric screwdriver operations 14 Count down from set number of screws Number of Screws LED decreases by one 15 Manually turn OFF electric screwdriver with...

Страница 26: ...will not proceed if no screws from the work set are tightened but are loos ened Note that although the screw may not be loosened count up will occur if the electric screwdriver is operated in reverse...

Страница 27: ...y if loosening of the screws is required after the final screw of the work piece has been tightened Work Reset Timer VR can be adjusted from 0 1 to 3 seconds Any reverse rotation at this stage will be...

Страница 28: ...ER BZ output Troubleshooting Investigate the issue in the table below and if an irregularity is found contact the supplying dealer Symptoms Confirmation Even if the main power switch is turned on it d...