24 Operation
SERIAL PROTOCOLS
There are two serial protocols available with the
8160. The “HINIKER” protocol is our original se-
rial communication standard. The “GENERIC”
protocol was developed to easily allow the 8160
to communicate to most mapping systems.
Refer to the Appendix for details on both com-
munication protocols.
If the “GENERIC” protocol is selected the 8160
will prompt you to turn Logging “ON” or “OFF”.
Selecting “LOGGING = ON” will instruct the
8160 to start sending data to the serial port once
per second. “LOGGING = OFF” turns this fea-
ture off. For most applications this is turned on.
With the “GENERIC” protocol selected the 8160
will now prompt you to enter a “FIELD #”. You
may enter 1 to 9999 using the and keys.
When using the 8160 with most mapping sys-
tems you should select the “GENERIC” protocol.
From the mapping systems menu select *”RA-
VEN 440” as the serial controller. Follow the set-
up instructions for setting up a 440.
SERIAL PROTOCOL
DISPLAY
COMMENTS and ACTIONS
Serial protocol settings are listed in the Options menu for each operating mode.
See “Options Menu” chart on how to access the Option Menu items.
PROTOCOL =
HINIKER
Available selections are “HINIKER” and “GENERIC”. If “GENERIC” is selected
then the 8160 will prompt you for “LOGGING ON/OFF” and a “FIELD # “
LOGGING = OFF
Selecting “LOGGING = ON” will instruct the 8160 to start sending data to the
serial port once per second. “LOGGING = OFF” turns this feature off
FIELD = 1
Available field identifier numbers are 1 to 9999
VALVE PROFILE
There are two Valve Profiles available with the
8160. They are called “A” and “B”. “A” is our
standard profile.
VALVE PROFILE
DISPLAY
COMMENTS and ACTIONS
Serial protocol settings are listed in the Options menu for each operating mode.
See “Options Menu” chart on how to access the Option Menu items.
VALVE PROFILE
= A
Available selections are “A” and “B”. Press the and keys to select either
“A”, or “B” then press SET.
SPEED SIMULATOR
DISPLAY
COMMENTS and ACTIONS
The speed simulator routine is located. in the Options menu for each operating
mode. See “ Options Menu” chart on how to access the Options menu items.
SIMULATOR
SPEED = OFF? Y
The available speeds are OFF and 1 through 9 MPH. Press the and keys
to change to the required speed then press SET.
* Note: Display values shown are factory default values. Values shown will be current setting.
SPEED SIMULATOR
The 8160 has a built in speed simulator. It will
allow you to set up you system without driving.
It can also be used as a temporary speed sen-
sor replacement in the case of a malfunctioning
speed sensor. It can be very helpful in trouble-
shooting control problems.
“B” has been modified to give a more linear re
-
sponse to change request so it tends to be more
aggressive.