Appendix 63
DWG. NO. 6655
SWATH CONTROL
The 8160 controller can be used with external
devices such as light bars that use swath control
to turn each boom section valve on and off.
If connected as shown below the 8160 will per-
form the application control while the swath con-
trol will be in control of the boom sections.
The 8160 considers a boom valve “on” if it has
12 volts applied to the control wire.
Connect the control valve wiring (Power, Ground,
and Control) as instructed in the Swath Control-
ler Manual. Connect the 3 control wires from the
8160 Boom cable to the valves along with the
control lines from the swath control unit. The re-
maining wires from the boom cable will not be
connected.
For the 8160 to work, all boom switches on the
8160 must be in the off position. When connect-
ed in this way the 8160 senses the state (On/Off)
of each boom section valve.
If all section valves are off, the Hiniker console
will be in Hold. The 8160 will operate as if it were
controlling the boom section valves.
Any Remote Run/Hold should be accomplished
through the swath control device. The 8160 will
go into Hold when sensing that all booms are
off. A Remote Run/Hold connected directly to the
Hiniker console will not turn the section valves
off when the console goes into Hold. The same
holds true when putting the Run/Hold switch on
the 8160 into the Hold position. Leave the Run/
Hold switch on the Hiniker console in the Run
position and the boom switches off.