Installation Instructions for:
105295-HEI Kit
Gen1 to Gen5
Control System
Configuration Code Chart and
Machine Option Definitions for
GS-1530, GS-1532, GS-1930, and
GS-932 Models
(after serial numbers GS3005-74999)
All configuration, programming and speed tuning
information can be found in the Service Manual. Refer
to the Service Manual for your machine.
How to Activate the Battery Drain
Alarm Option
1.
Pull out the red Emergency Stop button the the on
position at the ground controls.
2.
Push in the red Emergency Stop button to the off
position at the platform controls.
3.
Turn the key switch to p;platform control.
4.
At the platform controls, press and hold the lift
function select and speed select buttons, and pull
out the red Emergency Stop button to the on
position.
Outcome: The diagnostic display, at the platform
controls and the EMC will show “SC”.
5.
Release the lift finction select and speed select
buttons.
Outcome: The disganostic display will show the
current configuration.
6.
Press the speed select button.
Outcome: The “ones” digit setting will be
activated and the current “ones” setting will flash
in the diagnostic display.
7.
Press the horn button.
Outcome: A dot, located at the lower right of the
diagnostic display window, will become
illuminated. This indicates that the battery drain
alarm option has been activated.
8.
Turn the key switch to the off position.
Note: Any change in software settings will not take
effect until the key switch is turned to the off position.
Note: To deactivate the battery drain alarm option on a
machine which has the option activated, repeat this
procedure. When the ECM is in the “SC” mode and
the option is deactivated , there will not be an
illuminated dot in the diagnostic display window.
P/N 105294-HEI Rev.0
HEI
9/ 16