HM160 MAX
16
68
156.425 156.425
x
Non-Commercial
69
156.475 156.475
x
Non-Commercial
70
156.525 156.525
x
Non-Commercial
71
156.575 156.575
x
Non-Commercial
72
156.625 156.625
x
Non-Commercial (Inter-ship only)
73
156.675 156.675
x
Port Operations
74
156.725 156.725
x
Port Operations
77
156.875 156.875
x
Port Operations (Inter-ship only)
78A
156.925 156.925
x
Non-Commercial
79A
156.975 156.975
x
Commercial. Non-Commercial in Great Lakes only.
80A
157.025 157.025
x
Commercial. Non-Commercial in Great Lakes only
81A
157.075 157.075
x
U.S. Government only – Environmental protection operations.
82A
157.125 157.125
x
U.S. Government only
83A
157.175 157.175
x
U.S. Coast Guard only
84
157.225 161.825
Public Correspondence (Marine Operator)
84A
157.225 157.225
Non-Commercial
85
157.275 161.875
Public Correspondence (Marine Operator)
85A
157.275 157.275
Non-Commercial
86
157.325 161.925
Public Correspondence (Marine Operator)
86A
157.325 157.325
Non-Commercial
87
157.375 161.975
Public Correspondence Marine Operator)
87A
157.375 157.375
Non-Commercial
88
157.425 162.025
Public Correspondence only near Canadian border
88A
157.425 157.425
x
Commercial, Inter-ship only
Recreational boaters normally use channels listed as Non-Commercial: 68, 69, 71, 72, 78A.
Channel 70 is used exclusively for Digital Selective Calling (DSC) and is not available for regular voice
communications.
Channels 75 and 76 are reserved as guard bands for Channel 16 and are not available for regular voice
communications.
Notes:
1. The letter “A” following a channel number indicates simplex use of the ship station transmit side of an
international semi-duplex channel. Operations are different from that of international operations on that channel.
2. Channel 13 should be used to contact a ship when there is danger of collision. All ships of length 20 meters or
greater are required to guard VHF channel 13, in addition to VHF channel 16, when operating within U.S.
territorial waters.
3. Channel is Receive Only.
4. Channel 16 is used for calling other stations or for distress alerting.
5. Output power is fixed at 1 watt only.
6. Output power is initially set to 1 watt. User can temporarily override this restriction to transmit at high power.