background image

Table of Contents 

DI 24 01 

Page 4 of 34 

HI 800 201 E Rev. 1.00 

4.4

 

Configuring a Module Using ELOP II Factory.................................................... 22

 

4.4.1

 

Configuring the Inputs ............................................................................................ 22

 

4.4.2

 

Signals and Error Codes for the Inputs .................................................................. 22

 

4.4.2.1

 

Digital Inputs........................................................................................................... 22

 

5

 

Operation .............................................................. 23

 

5.1

 

Handling ................................................................................................................ 23

 

5.2

 

Diagnosis .............................................................................................................. 23

 

6

 

Maintenance .......................................................... 24

 

6.1

 

Faults ..................................................................................................................... 24

 

6.2

 

Maintenance Measures ........................................................................................ 25

 

6.2.1

 

Loading the Operating System ............................................................................... 25

 

6.2.2

 

Proof Test............................................................................................................... 25

 

7

 

Decommissioning .................................................. 26

 

8

 

Transport .............................................................. 27

 

9

 

Disposal ................................................................ 28

 

Appendix ............................................................... 29

 

Glossary ................................................................................................................ 29

 

Index of Figures.................................................................................................... 30

 

Index of Tables ..................................................................................................... 31

 

Index ...................................................................................................................... 32

 

 

Содержание HIMatrix DI 24 01

Страница 1: ...HIMatrix Safety Related Controller DI 24 01 Manual HIMA Paul Hildebrandt GmbH Co KG Industrial Automation Rev 1 00 HI 800 201 E...

Страница 2: ...HIMA directly HIMA appreciates any suggestion on which information should be included in the manual Equipment subject to change without notice HIMA also reserves the right to modify the written materi...

Страница 3: ...elated Analog Inputs 11 3 1 1 1 Reaction in the Event of a Fault 11 3 2 Equipment Scope of Delivery 11 3 3 Type Label 12 3 4 Assembly 13 3 4 1 Block Diagram 13 3 4 2 Front View 14 3 4 3 Status Indicat...

Страница 4: ...gnals and Error Codes for the Inputs 22 4 4 2 1 Digital Inputs 22 5 Operation 23 5 1 Handling 23 5 2 Diagnosis 23 6 Maintenance 24 6 1 Faults 24 6 2 Maintenance Measures 25 6 2 1 Loading the Operating...

Страница 5: ...ing Transport Disposal This manual distinguishes between the following variants of the HIMatrix system Programming tool Processor operating system Communication operating system SILworX Version 7 and...

Страница 6: ...rX ELOP II Factory Online Help Instructions on how to use ELOP II Factory Ethernet IP protocol INTERBUS protocol First Steps SILworX Introduction to SILworX using the HIMax system as an example HI 801...

Страница 7: ...rly marked 1 3 1 Safety Notes The safety notes are represented as described below These notes must absolutely be observed to reduce the risk to a minimum The content is structured as follows Signal wo...

Страница 8: ...Rev 1 00 1 3 2 Operating Tips Additional information is structured as presented in the following example i The text corresponding to the additional information is located here Useful tips and tricks a...

Страница 9: ...of values Protection class Protection class III in accordance with IEC EN 61131 2 Ambient temperature 0 60 C Storage temperature 40 85 C Pollution Pollution degree II in accordance with IEC EN 61131...

Страница 10: ...user program Faults in the wiring 2 3 Safety Precautions Observe all local safety requirements and use the protective equipment required on site 2 4 Emergency Information A HIMatrix system is a part...

Страница 11: ...ndards and test standards are specified in the certificate available on the HIMA website 3 1 Safety Function The module is equipped with safety related analog inputs 3 1 1 Safety Related Analog Inputs...

Страница 12: ...Rev 1 00 3 3 Type Label The type plate contains the following details Product name Bar code 1D or 2D code Part no Production year Hardware revision index HW Rev Firmware revision index FW Rev Operati...

Страница 13: ...3 Product Description HI 800 201 E Rev 1 00 Page 13 of 34 3 4 Assembly This chapter describes the layout and function of the plug in module 3 4 1 Block Diagram Test 24 Channels I O Bus Figure 2 Block...

Страница 14: ...3 Product Description DI 24 01 Page 14 of 34 HI 800 201 E Rev 1 00 3 4 2 Front View DI 24 01 Figure 3 Front View...

Страница 15: ...16 Yellow Off The related channel is inactive de energized Table 6 I O LEDs 3 5 Product Data General Operating voltage 24 VDC 15 20 wss 15 provided by a power supply unit with safe isolation in accord...

Страница 16: ...e into the rack 1 Insert the module as far as it can go without jamming it into the two guiding rails which are located on the upper and lower part of the enclosure 2 Apply pressure to the upper and l...

Страница 17: ...ered sequence to avoid improper connections Use the following terminals to connect the inputs Terminal Designation Function 01 I1 Input 1 02 I2 Input 2 03 I3 Input 3 04 I4 Input 4 05 I5 Input 5 06 I6...

Страница 18: ...ut wires 2 Activate noise blanking a signal must be present for at least two cycles before it is evaluated i Activating noise blanking increases the response time of the HIMatrix system i The measures...

Страница 19: ...an also performed when the controller is under voltage 2 The enclosure in use must be able to safely dissipate the generated heat The power dissipation of the module is 3 1 W at maximum depending on t...

Страница 20: ...e of I O modules can be plugged in to slots 3 8 The module slots in SILworX and ELOP II Factory are numbered as follows Module Slot on the rack Slot in SILworX Slot in ELOP II Factory PS 01 1 CPU COM...

Страница 21: ...xceeded 0x0008 FTT test 2nd Temperature threshold exceeded Module Error Code WORD R Module error code Coding Description 0x0000 I O processing if required with errors see other error codes 0x0001 No I...

Страница 22: ...UDINT R Slot number System Rack Slot Mod Type UINT R Type of module target value 0xFA05 64005dec Mod Error Code WORD R Error codes for the module Coding Description 0x0000 I O processing if required...

Страница 23: ...IMatrix base plate and does not require any specific monitoring 5 1 Handling Handling of the controller during operation is not required 5 2 Diagnosis A first diagnosis results from evaluating the LED...

Страница 24: ...acturer is authorized to repair the device module 6 1 Faults Refer to Chapter 3 1 1 1 for more information on the fault reaction of inputs NOTE If a failure occurs the module must be replaced to ensur...

Страница 25: ...e system downtimes to load a current version of the operating system into the controller Refer to the release list to check the consequences of the new operation system version on the system Load the...

Страница 26: ...01 Page 26 of 34 HI 800 201 E Rev 1 00 7 Decommissioning Remove the supply voltage to decommission the module Afterwards pull out the pluggable screw terminal connector blocks for inputs and outputs...

Страница 27: ...chanical damage HIMatrix components must be transported in packaging Always store HIMatrix components in their original product packaging This packaging also provides protection against electrostatic...

Страница 28: ...E Rev 1 00 9 Disposal Industrial customers are responsible for correctly disposing of decommissioned HIMatrix hardware Upon request a disposal agreement can be arranged with HIMA All materials must be...

Страница 29: ...ronic System PFD Probability of Failure on Demand probability of failure on demand of a safety function PFH Probability of Failure per Hour probability of a dangerous failure per hour R Read The syste...

Страница 30: ...Appendix DI 24 01 Page 30 of 34 HI 800 201 E Rev 1 00 Index of Figures Figure 1 Sample Type Label 12 Figure 2 Block Diagram 13 Figure 3 Front View 14 Figure 4 Label for Ex Conditions 19...

Страница 31: ...ers 11 Table 5 Status Indicators 15 Table 6 I O LEDs 15 Table 7 Product Data 15 Table 8 Specifications for Digital Inputs 15 Table 9 Terminal Assignment for the Inputs 17 Table 10 Module Slots 20 Tabl...

Страница 32: ...Appendix DI 24 01 Page 32 of 34 HI 800 201 E Rev 1 00 Index diagnosis 23 fault reaction digital inputs 11 part number 11 specifications 15 surge 18...

Страница 33: ......

Страница 34: ...1014 HIMA Paul Hildebrandt GmbH Co KG P O Box 1261 68777 Br hl Germany Tel 49 6202 709 0 Fax 49 6202 709 107 E mail info hima com Internet www hima com HI 800 201 E by HIMA Paul Hildebrandt GmbH Co KG...

Отзывы: