Alarm time regulation
The alarm time is adjustable from 180 at 600 seconds.
!
Disable the burglary system.
!
Keep the "PROGRAM" key pressed up to the LEDs blinking .
!
Keep the key pressed. The LED starts blinking slowly. Each blinking rises the time of
TEN SECONDS the alarm time, on a basic time of 120 seconds (2 minutes).
!
Set from 120 to 600 seconds (from 3 to 10 minutes) the alarm time.
!
Press three times the "PROGRAM" key to exit.
5
1 2 3 4
6
4
5
6
1
4
5
3
2
o
N
main power
fuse
power supply
e x c l u s i o n
opened
disarmed
system
zone
lamp.
lamp.
EXIT
ACCESS
alarm
memory
flash
flash
arm
zone
system
exclused
allarme
memoria
alarm
memory
ZONE CONTROL
green
red
led
acceso
led
impianto
zone
disinserito
aperte
uscita
entrata
allarme
memoria
impianto
zone
inserito
escluse
verde
rosso
o
N
main power
fuse
power supply
e x c l u s i o n
opened
disarmed
system
zone
lamp.
lamp.
EXIT
ACCESS
alarm
memory
flash
flash
arm
zone
system
exclused
allarme
memoria
alarm
memory
ZONE CONTROL
green
red
led
acceso
led
impianto
zone
disinserito
aperte
uscita
entrata
allarme
memoria
impianto
zone
inserito
escluse
verde
rosso
12V
Int
24h
A
B
C
D
RIT IMM
COM.
IMM2
COM. SIR. S.A.
3.7
Alarm enabling for main power supply absence
This operation consists in an alarm enabling, of few seconds, after 5 hours of main power
supply absence.
!
Disable the burglary system.
!
Keep the "PROGRAM" key pressed up to the LEDs blinking .
!
Press the key to enable/disable the function.
!
The LED blinking means that the function is enabled .
!
Press three times the "PROGRAM" key to exit.
8
1
3
4
5
7
6
8
1
2
7
8
4
5
3
o
N
main power
fuse
power supply
e x c l u s i o n
opened
disarmed
system
zone
lamp.
lamp.
EXIT
ACCESS
alarm
memory
flash
flash
arm
zone
system
exclused
allarme
memoria
alarm
memory
ZONE CONTROL
green
red
led
acceso
led
impianto
zone
disinserito
aperte
uscita
entrata
allarme
memoria
impianto
zone
inserito
escluse
verde
rosso
o
N
main power
fuse
power supply
e x c l u s i o n
opened
disarmed
system
zone
lamp.
lamp.
EXIT
ACCESS
alarm
memory
flash
flash
arm
zone
system
exclused
allarme
memoria
alarm
memory
ZONE CONTROL
green
red
led
acceso
led
impianto
zone
disinserito
aperte
uscita
entrata
allarme
memoria
impianto
zone
inserito
escluse
verde
rosso
12V
Int
24h
A
B
C
D
RIT IMM
COM.
IMM2
COM. SIR. S.A.
5X
PROTEC
5X
PROTEC
security
security
Содержание PROTEC5X
Страница 25: ...ITALIANO ENGLISH PROTEC5X 4 zones burglar central unit with electronic key USER S MANUAL security...
Страница 49: ...PROTEC5X Centrale antivol 4 zones avec clef lectronique ITALIANO FRANCAIS MANUEL DE L UTILISATEUR security...
Страница 73: ...PROTEC5X Central antirrobo 3 zonas 24h con llave electr nica ITALIANO ESPA OL MANUAL PARA EL USUARIO security...