When the installation is finished, it needs to connect the red/black conductors equipped
with faston coming from the power supplier to the battery. Be careful about connection polarity
(Red=positive [+] of the battery; Black=negative [-] of the battery), so that no cause great
damages to the connected devices.
After connecting the central unit and the siren batteries, it’s possible to power on the
system by the sectioning switch connected on the power supply/battery charger main power
clamps. The “RETE” LED signals the effective presence of the main voltage.
13Vcc regular output tension for volumetric detectors, telephone dialer, etc.
ATTENTION! Maximun current supplied: 650mA
13Vcc output tension on system enabled for the telephone dialer enabling.
aximum 3 supplementary SKI/M - /L - /NL connectors for electronic
SK key.
24h protection zone NC* line (immediated).
Zone 1 NC* line (d
Zone 2 NC* line (immediated).
11 - 12
Zone 3 NC* line (immediated).
13 - 14
13Vcc output tension in alarm condition for supplementary indoor sirens and
telephone dialer activation.
13 - 15
13Vcc output tension to recharge the autopowered siren. In alarm condition
this tension falls.
*
If the alarm zones are not used, the clamps must be arched.
The PROTEC5X and the don’t need the ground connection, but for safety reasons and for
the respect of the laws in vigor we suggest to make and test the ground connections of the all
devices that need it.
2.3
Connections
1 - 2
1 - 3
4 - 5 - 6 - 7
Output for m
8 - 12
9 - 12
elayed).
10 - 12
2.3.1
Additional SKI connectors for SK electronic key
The maximum distance of the connectors to the central unit is 200meters, and it’s possible
to connect maximum 3 connectors.
30
31
Installation
PROTEC5X - User’s manual
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15
A
B
C
D
SKI/NL
(in endowment)
Toward other
connectors
(optionals)
In series to
the 24h line
6S
ATTENTION!
The 12V7Ah battery must always be connected. Ensure of its efficient charge state,
measuring the tension by a volt-meter, after disconnecting the main power supply from
the power supplier/battery charger by the sectioning switch. Also in case of changing of
the lead battery it’s necessary to disconnect the main power supply from the power
supplier/battery charger, to avoid that the entire system burden on it.
Don’t connect on 13Vcc services power supply output of the central unit (clamps [1] and
[2] "+12V") a load beyond 650mA.
TMP/NL
(optional)
Antitearing
protection tamper
security
security
Содержание PROTEC5X
Страница 25: ...ITALIANO ENGLISH PROTEC5X 4 zones burglar central unit with electronic key USER S MANUAL security...
Страница 49: ...PROTEC5X Centrale antivol 4 zones avec clef lectronique ITALIANO FRANCAIS MANUEL DE L UTILISATEUR security...
Страница 73: ...PROTEC5X Central antirrobo 3 zonas 24h con llave electr nica ITALIANO ESPA OL MANUAL PARA EL USUARIO security...