Press the emergency OFF button in the
event of encountering a critical or dan-
gerous situation while sawing!
1
Open the water valve at the hydraulic unit (flow rate at least 7 l/min., pressure max. 6 bar).
2
Set the control switch on the hydraulic unit to the
"on"
(I) position.
3
Turn the current control knob
to the desired setting: depending on the power supply available, usually
between 32 and 63 amps (maximum power at 63 amps, reduced power at 32 amps).
4
Turn knob
and then back to position "II". The star (Y) - delta (
∆
) motor start-up procedure takes approx.
five seconds. Do not manipulate any other controls until the Y-
∆
start-up switching sequence is heard to be
completed.
5
Use the direction control knobs
,
and the speed control knob
to bring the saw head to the starting
position and then return the switches to the
"neutral/0"
position
6
Control knob
should then be used to set the desired speed (according to blade diameter)
or, respec-
tively, the oil flow rate
. The display
indicates the current operating pressure (bar).
7
Using control knobs
and
, pivot the saw arm / blade until the desired cutting depth is reached and
then return the knobs to the "neutral/0" position. Guideline: Please refer to the sticker on the rear of the
D-RC-LP 32 remote control unit for cutting depths, guide cuts and cutting sequence.
8
Use knob
to select sawing direction and set the speed control knob
to maximum. Optimise power
output by adjusting the current control knob
. Make the guide cut with a pressure of max. 110 bar.
9
Repeat step number 7 until the desired depth of cut is reached.
10
After reaching the final depth, use knobs
and
to move the saw arm into the 90° position (away from
the rail) and then use knobs
and
to move the saw head to the desired position on the rail. Turn the
speed control knob
(oil flow rate) back to zero and switch off the drive with switch
(the saw blade
stops rotating). Check again that all control knobs are in the
"neutral/0"
position. Finally, press in the
emergency
OFF
button
on the remote control unit.
11
Close the water valve on the hydraulic unit.
12
Switch off the hydraulic unit.
37
7. Operation
The sawing procedure and saw operation
Please refer to the D-LP 32 hydraulic unit application guidelines sticker, section 2.3.2, page 9.
7.2
D-RC-LP 32
Start
Ampere
II
I
32
63
45
100
1600 1200 1000 900 800
mm
80
60
40
3
4
7
8
9
2
6
1
10
5
Printed: 08.07.2013 | Doc-Nr: PUB / 5069667 / 000 / 01
Содержание D-LP 32
Страница 1: ...Operating instructions en D LP 32 DS TS 32 Printed 08 07 2013 Doc Nr PUB 5069667 000 01 ...
Страница 20: ...20 4 Technical data Rating plates 4 7 Printed 08 07 2013 Doc Nr PUB 5069667 000 01 ...
Страница 42: ...42 Printed 08 07 2013 Doc Nr PUB 5069667 000 01 ...
Страница 53: ...53 Printed 08 07 2013 Doc Nr PUB 5069667 000 01 ...
Страница 54: ...54 Printed 08 07 2013 Doc Nr PUB 5069667 000 01 ...
Страница 55: ...55 Printed 08 07 2013 Doc Nr PUB 5069667 000 01 ...