Descriptions
18/83
2.6.5
X901 – Sensor connector for NXHX-ENC and standard MMIOs
MMIO pin header connector
X901
for the NXHX-ENC (part number
7924.000).
This connector can also be used as interface for standard MMIO, BiSS and
EnDat signals, and for connecting UART (NXHX-RS232 adapter module)
and CAN (NXHX-CO adapter module) peripherals to the application CPU of
the netX 90.
For identifying the connector on the board, see position
(8)
in section
Positions of interfaces and operating elements
X901
Pin
Signal
No netX 90
X901 signal
EnDat
BiSS
NXHX-CO
NXHX-RS232
1
COM_IO0/
ADC3_IN2
AIM
ENDAT0_OUT BISS0_MO CAN0_APP_TX
CAN1_APP_TX
UART_APP
_TXD
2
MMIO4/
ADC0_IN0
SIN_SIN0
_HA
ENDAT0_IN
BISS0_SL CAN0_APP_RX
CAN1_APP_RX
UART_APP
_RXD
3
MII0_TXD
2/
ADC2_IN4
AI
ENDAT0_CLK BISS0_MA
–
UART_APP
_RTS#
4
MMIO6/
ADC1_IN0
COS_SIN120
_HB
ENDAT0_OE
BISS0_OE
-
UART_APP
_CTS#
5
GND
GND
-
-
GND
GND
6
+3V3
+3V3
-
-
+3V3
+3V3
7
GND
GND
-
-
PIO4
PIO4
8
MMIO3/
ADC3_IN3
SIN240_HC
-
-
PIO5
PIO5
9
MII1_TXC
LK/
ADC2_IN2
POT
-
-
RSTOUT
RSTOUT
10 GND
GND
-
-
-
-
Table 14: Pin assignments X901
Note:
If you intend to use
EnDat
or
BiSS
signals, make sure to set all
switches of
S700
to OFF position. For identifying
S700
on the
board, see position
(23)
in section
·
For technical details of the
NXHX-ENC
module, see section
·
For technical details of the
NXHX-RS232
module, see section
RS232 serial interface adapter
·
For technical details of the
NXHX-CO
module, see section
NXHX 90-MC | Device description
DOC200602HW01EN | Revision 1 | English | 2021-02 | Released | Public
© Hilscher 2021