Technical data
39/55
Feature
Description
Restrictions
RT over UDP not supported.
Multicast communication not supported.
DHCP is not supported.
The amount of configured IO-data influences the minimum cycle time
that can be reached.
Only 1 Input-CR and 1 Output-CR per AR are supported.
Little endian byte order not supported.
System Redundancy (SR-AR) and Dynamic Reconfiguration are not
supported.
The usage of PROFINET CombinedObjectContainer is not supported
SharedInput is not supported.
MRPD is not supported.
DFP and other HighPerformance-profile related features are not
supported.
Submodules cannot be configured or used by an AR in subslot 0.
The stack does not support usage of PDEV submodules
(InterfaceSubmodule or PortSubmodule) outside of slot 0. In addition
the InterfaceSubmodule is only supported in subslot 0x8000 and the
PortSubmodules are only supported in subslots 0x8001 and 0x8002.
Reference to stack version
V5.2
Table 33: Technical data PROFINET IO-Device
The maximum values for number of submodules, Multiple Application
Relations, Acyclic communication, and Diagnosis entries are configuration
parameters in the tag list of a firmware. Each of these features require
resources and have to be set in order to not exceed the available resource
(e.g. RAM) of a device.