In  manual  tracking  mode,  when  a  target  object  goes  directly  beneath  the  dome,  the  dome  will 
automatically rotate 180 degrees in horizontal direction to maintain continuity of tracking.   

Privacy Mask 

The  privacy  mask  allows  a  user  to  program  user-defined  areas  that  cannot  be  viewed  by  the 
operator  of  the  dome  system.  A  masked  area  will  move  with  pan  and  tilt  functions  and 
automatically adjust in size as the lens zooms telephoto and wide. 

3D Intelligent Positioning 

The  speed  dome  can  be  controlled  with  the  2  buttons  and  scroll  of  mouse  can  be  used  under 
PRIVATE-Code protocols with devices and client software. Click on a certain area and the device will 
move to the scene with corresponding point as the center. When a rectangular area is selected by 
left-clicking the mouse, device will move to its center and enlarge it. With right-clicking, the lens will 
zoom  in,  and  the  scroll  can  easily  make  the  lens  zooming,  and  mouse  operation  automatically 
incorporates zooming effect. 

Proportional Pan 

Proportional  pan  automatically  reduces  or  increases  the  pan  and  tilt  speeds  in  proportion  to  the 
amount  of  zoom.  At  telephoto  zoom  settings,  the  pan  and  tilt  speeds  will  be  slower  for  a  given 
amount of joystick deflection than at wide zoom settings. This keeps the image from moving too fast 
on the monitor when there is a large amount of zoom. 

Auto Focus 

The auto focus enables the camera to focus automatically to maintain clear video images.   

DAY/NIGHT Auto-switch 

The  speed  dome  delivers  color  images  during  the  day;  as  light  diminishes  at  night,  it  switches  to 
night mode and delivers black and white images with high quality. You can also switch it to NIGHT 
mode manually to increase the sensitivity in low light conditions. 

Slow Shutter 

Slow shutter is the function of extending the exposure time to accumulate more light when the light 
condition is low. Thus, the image can be brighter. 

Backlight Compensation (BLC) 

If the speed dome focuses on an object against strong backlight, the object will be too dark to be 
seen clearly. The BLC function can compensate light to the object in the front to make it clear, but 
this causes the over-exposure of the background where the light is strong. 

Wide Dynamic Range (WDR) 

The wide dynamic range function helps the speed dome provide clear images even under back light 
circumstances. When there are both very bright and very dark areas simultaneously in the field of 
view, WDR balances the brightness level of the whole image and provide clear images with details. 

White Balance 

White balance is the white  rendition function of  the speed dome to adjust the color temperature 
according to the environment automatically. It can remove the unrealistic color casts in the image. 

Patrol 

The high speed dome provides up to 8 patrols. In each patrol, user is allowed to specify the scanning 
track  by  a  group  of  user-defined  presets,  with  the  scanning  speed  between  two  presets  and  the 
dwell time at the preset separately programmable.   

Pattern 

A  pattern  is  a  memorized,  repeating  series  of  pan,  tilt,  zoom,  and  preset  functions  that  can  be 

Содержание IR Smart Speed Dome

Страница 1: ...Hikvision Digital Technology Co Ltd All Rights Reserved IR Smart Speed Dome User Manual UD 6L0201D1135A01...

Страница 2: ...ot hesitate to contact the dealer This manual is applicable to IR Smart Speed Dome This manual may contain several technically inaccurate points or printing errors and the content is subject to change...

Страница 3: ...ce must accept any interference received including interference that may cause undesired operation EU Conformity Statement This product and if applicable the supplied accessories too are marked with C...

Страница 4: ...over heat or fire hazard Please make sure that the power has been disconnected before you wire install or dismantle the speed dome When the product is installed on wall or ceiling the device shall be...

Страница 5: ...e cover avoid direct contact with the dome cover because the acidic sweat of the fingers may erode the surface coating of the dome cover Please use a soft and dry cloth when clean inside and outside s...

Страница 6: ...3 3 2 Configuring Privacy Mask 17 3 3 3 Configuring OSD Settings 19 3 4 Configuring PTZ Control Parameters 21 3 4 1 Configuring PTZ Parameters 21 3 4 2 Configuring Presets 23 3 4 3 Configuring Patrols...

Страница 7: ...an be controlled by the control keyboard DVR matrix etc Limit Stops The dome can be programmed to move within the limit stops left right up down which are configurable by the control keyboard DVR or c...

Страница 8: ...a to focus automatically to maintain clear video images DAY NIGHT Auto switch The speed dome delivers color images during the day as light diminishes at night it switches to night mode and delivers bl...

Страница 9: ...ormally closed And the alarm dwell time is configurable as well Manchester Code Self test The speed dome supports Manchester code self test for fault diagnostic You can enable the Manchester code diag...

Страница 10: ...485 Failure Diagnostics In the presence of failure at the transmitting and receiving terminals of RS 485 communications the speed dome is capable of performing self test and detecting the fault result...

Страница 11: ...ions of the System Information System Info Description TYPE The model of the speed dome SN The serial number of the speed dome ADDRESS The default communication address of the speed dome COM Format Th...

Страница 12: ...can choose the preset number from the list in the PTZ control panel Please refer to table below for details For instance preset 99 is the Start auto scan If you call the preset 99 the speed dome star...

Страница 13: ...0 Set Pattern 1 72 Call Pattern 3 71 Set Pattern 2 72 Set Pattern 3 2 4 On Screen Displays The speed dome supports following on screen displays Zoom Identifies the amount of magnification The format i...

Страница 14: ...PRIVACYS ALARMS AUXS CLEAR SETTINGS FOCUS ZOOM LIMIT ZOOM SPEED SLOW SHUTTER AUTO FLIP PROPORTION AL PAN PARK ACT SCAN SPEED IMAGE FREEZE DOME SPEED PRESET PEED LIMIT STOP PARK TIME REBOOT DOME LANGU...

Страница 15: ...the speed dome 4 Call preset 95 from the preset list in the PTZ control panel of the DVR MAIN MENUS SYS INFO DOME SETTINGS RSTORE DEFAULTS RSTORE CAMERA RSBOOT DOME LANGUAGE ENGLISH SET TITLE OFF EXIT...

Страница 16: ...t system information of the speed dome as shown in Figure 3 2 including model address protocol etc The information shown on this submenu is similar to the system information shown after the power up a...

Страница 17: ...255 If the SOFT ADDR ACTIVE is set as OFF the hard address set by the DIP switch is the valid address of the speed dome Task 2 Set the broadcast address of the speed dome When the BROADCAST ADDRESS i...

Страница 18: ...left right up down direction buttons to adjust the view angle 3 Click IRIS button to confirm and exit IR LED Parameters IR PARAMETER IR SENSITIVITY LOW N M LED CURRNT 2 FAR LED CURRNT 2 REFERENCE HEI...

Страница 19: ...menu Protocol settings You can set the PROTOCOL STATUS SET as ON or OFF and set the PROTOCOL SET as AUTO MATCH PELCP P PELCO D Private code etc RS 485 checksum setting You can set the 485CHECK SET as...

Страница 20: ...ting and zooming 3 Click IRIS button to save the settings Setting the focus limit Purpose This function is used to limit the minimum focus distance You can configure the focus limit longer when the ta...

Страница 21: ...he shutter speed Purpose The speed of the electronic shutter controls the amount of light entering the lens in a unit of time a second You can manually configure the shutter speed for the speed dome a...

Страница 22: ...u can switch it to DAY mode in normal lighting conditions Note You can also call preset 39 to set the IR cut filter mode to DAY mode and call preset40 to set it as NIGHT mode 2 D N level The D N level...

Страница 23: ...OMP value from 0 to 14 The default value is 7 White balance You can set WHITE BALANCE mode as AUTO INDOOR OUTDOOR SELFDEF self defined ATW auto tracking and HAUTO half auto AUTO In Auto mode the dome...

Страница 24: ...wn direction buttons to select a mask number for configuration 3 Click IRIS again to confirm and exit the editing mode Note The configurable privacy mask numbers vary depending on the camera models 3...

Страница 25: ...play of the dome name PTZ control information viewing direction etc Display the dome title Steps 1 Enter the dome title setting menu MAIN MENUS SET TITLE 2 Click IRIS to enter the editing mode 3 Click...

Страница 26: ...e title in the lower right corner or call preset 13 twice within 5 seconds to exit the title setting menu and display the title in the lower left corner or call preset 14 twice within 5 seconds to exi...

Страница 27: ...heast East Southeast South Southwest West Northwest Note The due north direction is 0 It is also the factory default initial position 3 4 Configuring PTZ Control Parameters Purpose You can configure p...

Страница 28: ...in the process of performing external alarm linked actions Image freeze This feature enables the live view to switch directly from one scene defined by a preset to another without showing the middle a...

Страница 29: ...ply click the calling button to view the desired image position TASK 1 Set a preset Steps 1 Move the cursor to enter preset configuration submenu MAIN MENUS DOME SETTINGS PRESETS PRESETS PRESET NUM 1...

Страница 30: ...he letter number symbol list to the label 5 Click FOCUS to exit the character lists and click IRIS again to confirm and exit the submenu LABEL PRESET 1 INS LOWCASE a b c d e f g h I j ZOOM DELETE CONT...

Страница 31: ...configuration submenu MAIN MENUS DOME SETTINGS PATROLS 2 Choose the patrol number Steps 1 Move the cursor to PATROLS NUM and click IRIS to enter edit mode 2 Click the up and down direction buttons to...

Страница 32: ...sequence for a patrol Press IRIS to save the current settings or press IRIS to cancel and return to the previous menu Task 2 Preview the patrol Move the cursor to PREVIEW and click IRIS to preview th...

Страница 33: ...NING 100 BACK EXIT Figure 3 19 Pattern Configuration Menu Task 1 Set a pattern Steps 1 Move the cursor to enter the PATTERNS submenu MAIN MENUS DOME SETTINGS PATTERNS 2 Choose the pattern number Steps...

Страница 34: ...RIS to delete the pattern Note If you delete the current pattern the following pattern will also be deleted E g if pattern 2 is deleted pattern 3 and pattern 4 will be deleted as well Clear all the pa...

Страница 35: ...he cursor to TASK ACTION and click the IRIS to enter edit mode 2 Click the up and down direction buttons to select the task action from preset 1 to 8 pattern 1 to 4 patrol 1 to 8 panning scan tilting...

Страница 36: ...ve the cursor to CLEAN TASK and click IRIS to delete the time and action of the current task 3 4 6 Configuring Zones Purpose ZONE submenu is used to divide the scene into several parts with user defin...

Страница 37: ...one it will switch to ON automatically if you delete the zone the ZONE STATUS will switch to OFF Task 2 Clear the zone settings Move the cursor to CLEAR ZONE and click IRIS to clear all the settings o...

Страница 38: ...LT LOST 0 CAMERA LOST 0 BACK EXIT Figure 3 26 Self diagnostics 3 5 Configuring Smart Settings Purpose The speed dome tracks the moving objects automatically after you configure this function Steps 1 E...

Страница 39: ...configured 3 Click IRIS again to confirm and exit edit mode of this column Note You can configure up to 7 alarms 3 Configure the alarm input Steps 1 Move the cursor to ALARM INPUT and click the IRIS...

Страница 40: ...the next one after the user defined interval You can set the on ALARM SEQUENCE submenu from 1 to 200 seconds 3 Configure the alarm rest delay If there s a linkage action has already been triggered by...

Страница 41: ...er that you want to link the auxiliary output to 2 Move the cursor to AUX and click IRIS to configure the auxiliary output to the alarm You can choose NONE to disable auxiliary alarm outputs choose 1...

Страница 42: ...E OPEN QUIT CLOSE Figure 3 30 Set the Password 3 7 3 Restoring Default Dome Settings Purpose You can reset all dome settings to factory default parameters as shown in the table below Note Dome setting...

Страница 43: ...s Off Time display Off Zoom azimuth elevation and preset label display Display for 2 seconds 3 7 4 Restoring Default Camera Settings Enter MAIN MENUS RESTORE CAMERA Click IRIS to restore the camera se...

Страница 44: ...Hikvision Digital Technology Co Ltd All Rights Reserved...