Proportional Pan
Purpose:
If you enable this function, the pan/tilt speeds change according to the amount of zoom. When
there is a large amount of zoom, the pan/tilt speed will be slower for keeping the image from
moving too fast on the live view image.
You can set
PROPORTIONAL PAN
to
ON
or
OFF
to enable/disable the function.
Note:
This function is enabled automatically while setting the patterns.
Park time and actions
Purpose:
This feature allows the speed dome to start a predefined action (park action: scan, preset, pattern,
etc.) automatically after a period of inactivity (park time).
You can set
PARK TIME
from 5 to 720 seconds and set the park action (
PARK ACT
) as preset 1 to 8,
pattern 1 to 4, patrol 1 to 8, pan scan, tilt scan, random scan, frame scan, panoramic scan, day mode,
night mode or none.
Note:
If no control signal is received after the park time under the following circumstances, no park
actions will be performed: in the process of performing dome actions by calling special presets; or in
the process of performing external alarm linked actions.
Image freeze
This feature enables the live view to switch directly from one scene defined by a preset to another,
without showing the middle areas between these two, to ensure the surveillance efficiency. It can
also reduce the use of bandwidth in a digital network system.
You can set
IMAGE FREEZE
on to enable this function.
PTZ speed
Purpose:
You can define the speed of the dome movements.
(1)
DOME SPEED:
the manual movement speed can be set as
HIGH
,
MID
or
LOW
.
(2)
SCAN SPEED:
scan speed defines the scan degree per second of panning scan, tilting scan, frame
scan, random scan and panoramic scan. Scan speed is adjustable from 1 to 40 degrees per
second.
(3)
PRESET SPEED:
the speed of calling a preset can be set from level 1 to 8. The higher level
corresponds to the faster speed to call a preset.
Limit stops
Purpose:
The dome can be programmed to move within the configurable limit stops (left/right, up/down).
Steps:
1.
Move the cursor to
LIMIT STOPS
and click
IRIS+
to set it
ON
to enable this feature. Click
IRIS+
again to confirm.
2.
Move the cursor to
<SETTING STOPS>
and click
IRIS+
. You will see the message
SET LEFT LIMIT
on the screen.
3.
Click the direction buttons in the PTZ panel to configure the left limit stop. Click
IRIS+
to confirm.