5.3.2
Multipoint Calibration
Before You Start
Arrange a staff (Operation staff) person to perform the calibration operation in the client software, and a staff
(Calibration staff) person to cooperate with the calibration.
1.
In the calibration page, select
Multipoint Calibration
as the calibration mode.
2.
Select equally distributed calibration points on the center line of the radar detection field (refer to the
following figure to select points).
Figure 5-9 Multipoint Distribution Instance
It is required to set three equally distributed calibration points with multipoint calibration.
3.
According to the calibration points, ask the calibration staff to move to a calibration point, and refer to step
2 to step 5 in
One Point Calibration
to calibrate the calibration point.
4.
When the first calibration point is calibrated completely, let the calibration staff move to the next
calibration point after the yellow track disappears. And then refer to step 2 to step 5 in
One Point
Calibration
to calibrate the calibration point. Follow this process to complete all calibration point positions
in turn.