Table 2-5 Parameter Setting
Parameter Name
Description
Enable
Check Enable.
Arming Camera
Select the desired camera to count the personnel appearance
frequency.
List to Filter
Filter the personnel in list library so that those personnel will not be
counted.
Filtering Threshold
Compare the similarity between face captured by camera and that of
face list library. The server will not count personnel appearance
frequency when the similarity is larger than or equal to the set value.
Times
Frequency alarm will be generated only when the appeared times is
larger than the configured times.
Capture Interval (min) The internal of face picture capture for the same personnel. (Unit:
minute)
Similarity
Compare the similarity between newly captured face pictures and all
captured face pictures. The server will count appearance frequency for
the same personnel when the similarity is larger than or equal to the
configured value.
Day Range
The statistics period of personnel appearance frequency. The data of
the earlist day will be covered by the newly-added data if the actual
number of days is greater than this value.
Time Segment
Set time period to count personnel appearance frequency.
Intelligent Fusion Server User Manual
23