PTZ menu description
Select channel:
Select one PTZ camera.
RS-485 parameters:
Including baudrate, data bit, stop bit, parity, flow control, etc. These
parameters must be the same as those PTZ Protocols.
PTZ address:
Each PTZ has one different address.
PTZ type:
DVR had the following PTZ protocol: YouLi, LinLin-1016, LinLin-820, Pelco-p,
DM DynaColor, HD600, JC-4116, Pelco-d WX, Pelco-D, VCOM VC-2000, NetStreamer,
SAE/YAAN, Samsung, Kalatel-312, CELOTEX, TLPelco-p, TLHHX-2000, BBV, RM110,
KC3360S, ACES, ALSON, INV3609HD, Howell, Tc Pelco P, Tc Pelco D, AUTO-M, AUTO-H,
ANTEN, CHANGLIN, DeltaDome, XYM-12, ADR8060, EVI-D30, DEMO-SPEED,
DM-PELCO-D, ST832, LC-D2104, HUNTER, A01, TECHYIN, WEIHAN, LG, D-MAX,
Panasonic, KTD-348, infinova, PIH-7625, LCU, DennarDome, etc. Other PTZ protocols will be
added with the new firmware.
Note: In DVR “PTZ” menu, if you select Pelco-P protocol, when you setup PTZ address,
please plus or minus one compared with Camera ID. For example, if camera ID is 2, the DVR
PTZ address is set as ID 3.
Preset setup:
Preset is using one number to represent the camera’s position, zoom, focus and
iris. Move “Active Frame” to “Setup” button on the right side of “Preset” item, press
[
ENTER
]
key
to enter preset setup menu. You can save 128 preset numbers. Please make sure the PTZ supports
preset function before you setup preset.
Sequence setup:
Each sequence is made up of several curise points. Each cruise point
includes one preset number, dwell time and dwell speed. Please make sure the PTZ you are using