User Manual of Thermal Network Positioning system
© Hikvision
61
Expert Mode:
Figure 5-27
Temperature Measurement Configuration
1)
Adjust the image to the scene for temperature measurement with the PTZ control
panel. Save current scene as certain preset.
You can set the preset in live view interface before and call the preset in the
temperature measurement and alarm interface.
You can set/ call/ clear the preset in temperature measurement interface.
2)
Set the alarm rule: Select a temperature measurement rule from the rule list and
configure the parameters.
Name: You can customize the rule name.
Type: Select Point, Line, or Frame as rule type.
Emissivity: Set the emissivity of your target. The emissivity of each object is
different, you can refer to the Quick Start Guide Appendix for details.
Distance (m): The straight-line distance between the target and the device.