Control Panel User Manual
85
3.2.24
Control Panel Soft Recovery
For control panel soft recovery; see the command below:
{master code} + {*} + {6} + {8} + {#}
All unissued CID logs will not be reissued. Newly generated report will
be issued after system recovery.
The timer of the test report will not be cleared, and will remain the
value before recovery till the recovery processes being completed.
3.2.25
Current Fault Tone Disabling
To disable the current fault tone; see the command below:
{*} + {5} + {6} + {#}
If there are new faults, the prompt sound will re-Tip.
3.2.26
Test Report Manually Triggering
To trigger test report manually; see the command below:
{password} + {*} + {6} + {1} + {#}
One operation generates one test report. It is used to test the communication
between the control panel and center after installing the system or during the
inspection.
3.2.27
Keypad Locking and Unlocking
If a user failed to operate for five times, the keypad will be locked for 30
seconds. During the lock duration, the keypad backlight blinks and all of the
key operations are invalid. The keypad will be unlocked after 30 seconds.
3.2.28
Exiting the Operation
See the command below to exit the operation.
{*}{#}
Содержание DS-19A08-F/Kx
Страница 1: ...Control Panel User Manual 1 UD 6L0206D1044A02 Network Security Control Panel User Manual...
Страница 13: ...Control Panel User Manual 13 Chapter 2 Installation and Wiring 2 1 Main Board Overview...
Страница 100: ...Control Panel User Manual 100 2 Click to enter the interface of adding a network user...
Страница 130: ...Control Panel User Manual 130...
Страница 156: ...Control Panel User Manual 156...
Страница 157: ...First Choice for Security Professionals...