Control Panel User Manual
79
disarming (current status) into arming immediately. The exiting delay of
partition is 0.
3.2.3
Stay Arming
Operation Method: {User password} + {
*
} + {
4
} + {#}.Take the password 1234
as an example, and the operation is shown as follows:
{1} + {2} + {3} + {4} + {*} + {4} + {#}
After the operation is completed, the partition will change the status of
disarming (current status) into arming immediately. The bypass-supported
zone of the partition will do auto-bypass simultaneously.
3.2.4
Zone Bypass/Recovery
After bypassing a zone, all the alarm devices in this zone will be blocked. ; see
the command below
{User password} + {bypass} + {Zone Number} + {#}
For continuous bypass/ recovery; see the command below:
[
1234
]
[
1
]
[
Bypass
]
[
#
]
+
+
+
[
2
]
[
Bypass
]
[
#
]
+
+
[
Bypass
]
[
#
]
+
+
[
8
]
……
15 Seconds
Continuous operation of multi-zone bypass/ recovery should be completed
within 15 seconds
3.2.5
Group Bypass
After a partition is conducted with group bypass, all the alarm devices in
group-bypass supported zone of the partition will be blocked. See the
command below.
{User Password} + {*} + {4} + {1} + {#}
Содержание DS-19A08-F/Kx
Страница 1: ...Control Panel User Manual 1 UD 6L0206D1044A02 Network Security Control Panel User Manual...
Страница 13: ...Control Panel User Manual 13 Chapter 2 Installation and Wiring 2 1 Main Board Overview...
Страница 100: ...Control Panel User Manual 100 2 Click to enter the interface of adding a network user...
Страница 130: ...Control Panel User Manual 130...
Страница 156: ...Control Panel User Manual 156...
Страница 157: ...First Choice for Security Professionals...