Note
•
Digit 1, 2, 3, 4 are used to coding the sub module address; Digit 5, 6, 7 are
reserved; Digit 8 is a resistance (120Ω) is you set it as on.
•
Valid sub module address range is 1 to 8. The No. should be unique for sub
modules that connected to the same main unit.
The sub module address and corresponding switch status as below.
Table 3-1 Description
Sub
Module
Address
1
2
3
4
5
6
7
8
Digit 1
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Digit 2
OFF
ON
ON
OFF
OFF
ON
ON
OFF
Digit 3
OFF
OFF
OFF
ON
ON
ON
ON
OFF
Digit 4
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
3.2 Two-Module Installation
3.2.1 Two-Module Surface Mounting
Module Door Station Quick Start Guide