Figure 4-41 Partition Page
Operations for a Single Partition
• Away: When all the people in the detection area leave, turn on the Away mode to arm all zones
in the partition after the defined dwell time.
• Stay: When the people stays inside the detection area, turn on the Stay mode to arm all the
perimeter burglary detection (such as perimeter detector, magnetic contacts, curtain detector in
the balcony). At the meantime, the detectors inside the detection area are bypassed (such as PIR
detectors). People can move inside the area and alarm will not be triggered.
• Disarm: In Disarm mode, all the zones in the partition will not trigger alarm, no matter alarm
events happen or not.
• Clear Alarm: Clear all the alarms triggered by the zones of the partition.
Operations for All Partitions
• Away: When all the people in the detection area leave, turn on the Away mode to arm all zones
in all partitions after the defined dwell time.
• Stay: When the people stays inside the detection area, turn on the Stay mode to arm all the
perimeter burglary detection (such as perimeter detector, magnetic contacts, curtain detector in
the balcony) set in all the zones of all partitions. At the meantime, the detectors inside the
detection area are bypassed (such as PIR detectors). People can move inside the area and alarm
will not be triggered.
• Disarm: In Disarm mode, all the zones of all partitions will not trigger alarm, no matter alarm
events happen or not.
• Clear Alarm: Clear all the alarms triggered by the all the zones of all the partitions.