SC5000 Series Smart Camera Quick Start Guide
v
components, etc. must share the same ground.
●
If the device is powered on and off frequently, it is necessary to strengthen the voltage isolation,
and consider adding a DC/DC isolation power supply module between the device and the adapter.
●
The device can be powered by 220 VAC with low-power equipment, but make sure to avoid the
same power supply as servo motors/high-power equipment.
●
Use a shielded network cable to connect to the device.
●
If you use a self-made network cable, make sure that the shielding shell at the aviation head is
well connected to the aluminum foil or metal braid of the shielding cable.
●
The control cable of the device and the power cable of the industrial light source must be wired
separately to avoid bundled wiring.
●
The power cable, data cable, signal cable, etc. of the device must be wired separately. Make sure
to ground them if the wiring groove is used to separate the wiring and the wiring groove is metal.
Personnel Requirement
Quality requirements for installation and maintenance personnel: Qualification certificate or
working experience in weak current system installation and maintenance, and relevant working
experience and qualifications. Besides, the personnel must possess the following knowledge and
operation skills:
●
The basic knowledge and operation skills of low voltage wiring and low voltage electronic circuit
connection.
●
The ability to comprehend the contents of this manual.
Contact Information
Hangzhou Hikrobot Technology Co., Ltd.
No. 399 Danfeng Road, Binjiang District, Hangzhou, 310051, China
E-mail: [email protected]
Website: https://en.hikrobotics.com/
Содержание SC5000 Series
Страница 1: ...SC5000 Series Smart Camera Quick Start Guide ...
Страница 31: ...UD26897B ...