15
English
en
7. How to use the LED light
While the switch is pulled, the LED light will automatically light up the tip
portion of the tool. The LED light will automatically turn off 10 seconds after
the switch is released. The LED light also functions as a warning signal that
lights up during use.
WARM-UP
If in cold weather, you should warm up the tool for 30-60 seconds so that the
hydraulic oil reaches the proper viscosity. Pull trigger-switch (ON) to extend
piston then release the switch (OFF) when it has reached its full stroke. Repeat
5-7 times without rebar.
STOPPER BOLT ADJUSTMENT
The adjustable stopper functions to maintain the rebar in the correct position
during cutting and must be properly set for each size of rebar before making a
cut. Screw in the stopper to provide sufficient clearance for the rebar. Keeping
rebar at right angles (90 degrees) to front cutter block, screw out the stopper
until it is just touching the rebar. Once set, the stopper needs no further
adjustment while cutting rebar of the same diameter, but must be reset for a
different size rebar.
Safeguard
Function
LED Light Display
Corrective Action
Overburden
Protection
On 0,1 second/off 0,1 second
If the operating with the shift
knob set on HIGH, adjust to
LOW and continue operation.
Remove the cause of the over-
burdening.
Reactive Force
Control
Remove the cause of the over-
burdening. When operating
the tool, firmly hold the tool to
make sure it doesn’t jerk.
Temperature
Protection
On 0,5 second/off 0,5 second
Allow the tool and battery
thoroughly cool.