Array Type 

 

JBOD: Just a Bunch of Disks 

 

RAID 0: Striping 

 

RAID 1: Mirroring 

 

RAID 5: Rotating Parity bit (Single parity) 

 

RAID 6: Rotating Parity bit (Dual parity) 

 

RAID 10: Striping Mirrored array 

 

RAID 50: Stripping RAID 5 array 

Each RAID level has its pros and cons based on the application you use it for (Note: Refer to RAID level 
Quick Reference.) 
Array Name 
Name displayed in Logical Device Information (Default: RAID_<level>_<array number>)

 

Initialization Method 
Initialization of a disk sets all data bits to 0, essentially clearing all the data on the drive. It is important 
to initialize disks as previous data physically stored on the drive may interfere with new data. 

 

Keep Old Data: This option skips the initialization process and all data on each physical disk of 
the array will be untouched. 

 

Quick Init: This option grants immediate access to the RAID array by skipping the initialization 
process, but it will delete all data. NoteSkipping initialization is generally not recommended 
as residual data on disks may interfere with new data in the future. 

 

Foreground: The array initialization process will be set at high priority. During this time array 
is not accessible, but the initialization process will complete much faster. 

 

Background: The array initialization process will have a lower priority. During this time the 
array will be accessible, but the initialization process will take much longer to complete. 

 
Note: 

 

Initializing takes a significant amount of time (approximately 2 hours per one TB). 

 

Fully initializing the array will completely zero out the data on the disks, meaning the disk will 
be completely wiped and every bit on the disk will be set to 0. Foregoing initialization means 
the array will still be created, and you can still write new data onto the array. But when your 
array requires rebuilding, residual data left behind may interfere with the process. 

Cache Policy (Default: Write Back) 
Write Back: 

 

Any data written to the array will be stored as cache, resulting in better I/O performance at 
the risk of data failures due to power outages. Data will be stored as cache before it is 
physically written to the disk; when a power outage occurs, any data in the cache will be lost. 

Write Through: 

 

Data written to an array is directly written onto the disk, meaning lower write performance 
for higher data availability. Without cache acting as a buffer, write performance will be 
noticeably slower but data loss due to power outages or other failures is significantly 
minimized. 

Block Size (default: 512K) 
Adjusting the block size towards your disk usage can result in some performance gain.  
 
In a typical RAID configuration, data of the virtual drive is striped (or spread across) the physical 
drives. Having a smaller array block size will increase the likelihood of accessing all physical drives 

Содержание RocketStor 6661A-mSAS1

Страница 1: ...1 RocketStor 6661A mSAS1 User Manual 5 4 18 Revision 1 00 HighPoint Technologies Inc...

Страница 2: ...C Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and i...

Страница 3: ...alling the Driver 15 Installing the HighPoint RAID Management WebGUI 15 How to Login to the HighPoint RAID Management 16 Remote Login 16 Formatting the RAID Volumes 17 Section 3 Software Setup for Mac...

Страница 4: ...fication 40 SMTP Setting 40 Add Recipient 41 Event 42 Storage Health Inspector SHI 43 Scheduler 43 How to Create a New Verify Task 44 Recover 44 Section 5 Troubleshooting 45 Handling Critical Arrays 4...

Страница 5: ...A mSAS1 enclosure Quick Installation Guide Power Adapter Thunderbolt 3 Cable Before getting started check to see if any items are missing damaged or incorrect If you discover any discrepancies please...

Страница 6: ...rt Windows 10 macOS 10 10 or later Operating Environment Work Temperature Range 5 C 55 C Relative Humidity Range 5 60 non condensing Storage Temperature 20 C 80 C MTBF 920 585 hours Certification Appr...

Страница 7: ...7 Section 1 Hardware Installation Hardware Overview Panel Layout Front View Panel Layout Rear View...

Страница 8: ...ac System with ThunderboltTM 3 support Windows 10 macOS 10 10 or later Enclosure Setup 1 Connect the Power Adapter to the RocketStor 6661A mSAS1 2 Connect the RocketStor 6661A mSAS1 to the host system...

Страница 9: ...olt Device connection 2 Select Always Connect from the drop down menu then click OK Driver Installation Drivers provide a way for your operating system to communicate with your new hardware Updating t...

Страница 10: ...dows logo on the bottom left of the screen 4 Select Device Manager 5 Under Other Devices RAID Controller should appear 6 Right click on RAID Controller and select Update driver 7 Select Browse my comp...

Страница 11: ...8 Select Browse 9 Find the driver folder downloaded and extracted previously and select the x32 folder if using a 32 bit system or the x64 folder if using a 64 bit system Then select OK 10 Select Nex...

Страница 12: ...ou should see the below appear on your screen 12 Restart your system 13 To double check that the driver installed properly in the Storage controllers tab in Device Manager make sure the RocketRAID 644...

Страница 13: ...er Version 1 Go to Device Manager and click on the Storage controllers tab 2 Right click on the RocketRAID 644LS SATA Controller and select Properties 3 Click the Driver tab and look at the Driver Ver...

Страница 14: ...ech com USA_new series rs6661a msas1 download htm 2 Go to Device Manager 3 Click on the Storage controllers tab 4 Right click on the RocketRAID 644LS SATA Controller and select Update Driver 5 Click B...

Страница 15: ...D array Using the management utilities and menus offered by the WebGUI you would be able to access create and maintain your RAID arrays New features are continually added to the interface The most upd...

Страница 16: ...n your desktop Opening your preferred web browser and typing http localhost 7402 in the address bar Note You can set the password under the Setting tab Remote Login A user connected to a local network...

Страница 17: ...array as a logical disk However the array will not be accessible until it is formatted by the operating system Format the volume when you have finished the following procedures 1 Set up the RocketStor...

Страница 18: ...ost likely need to use MBR for bootable drives b GPT partition table has no capacity limit but cannot be bootable unless your PC motherboard contains UEFI firmware 4 Once initialized right click the u...

Страница 19: ...with the name and letter you assigned Please note your disk may initially appear offline to the operating system and you may have to bring it online 1 In Disk Management right click the disk you wish...

Страница 20: ...st driver software for the RocketStor 6661A mSAS1 from our website http www highpoint tech com USA_new series rs6661a msas1 download htm 2 Mount and enter the downloaded folder 3 Run the HighPointRR p...

Страница 21: ...21 Checking Driver Installation 1 Select the Apple logo in the top left part of the screen 2 Select About this Mac 3 Select System Report 4 Select the Thunderbolt tab on the left...

Страница 22: ...22 5 Check that RocketStor 6661A is present 6 Select the PCI tab on the left 7 Check that the RocketRAID 644LS SATA Controller is present...

Страница 23: ...from http www highpoint tech com USA_new series rs6661a msas1 download htm 2 Mount and enter the downloaded folder 3 Run the HighPointWebGUI pkg package 4 Follow the on screen installation instruction...

Страница 24: ...formatted by the operating system Format the volume when you have finished the following procedures 1 Set up the RocketStor 6661A mSAS1 2 Install Driver and WebGUI software 3 Create an Array For Mac u...

Страница 25: ...ption near the top 4 Type in the name you want to use for your RAID array and select the format and scheme Then select Erase 5 After the erase process is complete select Done 6 Your RAID array is now...

Страница 26: ...key things Create and remove arrays Monitor disk health Update firmware and BIOS Change enclosure settings Troubleshoot faulty drives View general system overview Tab Name Function Global View View HB...

Страница 27: ...int controllers connected HBA Properties Host Adapter Model Model the model name of the controller Controller count number of controllers detected Enclosure count number of enclosures detected Physica...

Страница 28: ...e the firmware of the controller in this tab as well Controller Information The Controller tab displays more detailed information such as firmware version and condition of the controller To update the...

Страница 29: ...on device location example 1 2 states controller 1 channel 2 Write Cache Enable Disable enabling write cache will speed up write operations Max Free space on the disk that is not configured in an arra...

Страница 30: ...where you can edit delete and maintain your RAID configurations as well as review the Physical Device information The Logical tab has the following functions Create Array Spare Pool Logical Device Res...

Страница 31: ...ring this time the array will be accessible but the initialization process will take much longer to complete Note Initializing takes a significant amount of time approximately 2 hours per one TB Fully...

Страница 32: ...g RAID levels disk capacities are limited by the smallest disk For example consider the following You have 3 drives connected to the enclosure The first drive is 6 TB the second is 4 TB and the third...

Страница 33: ...e minimizes the chances of a data loss by reducing the time an array is in the critical status Logical Device The Logical device including your RAID arrays and the individual disks your system detects...

Страница 34: ...s off the selected RAID array once powered off the physical disks can be safely removed from the RAID controller Verify verifies the integrity of the RAID array Change Cache Policy toggles between Wri...

Страница 35: ...sk Insert new disk Reinserting the same disk should trigger the rebuilding status since data on the disk would be recognized If you insert a new disk clicking Add Disk will give you the option to sele...

Страница 36: ...you want to change a Select a different RAID level to Migrate For example if you want to change a RAID 0 array you will need to select a different RAID level such as RAID 5 or 6 b Select the same RAI...

Страница 37: ...del number of the drive connected Capacity total capacity of the drive Max Free total capacity that is not configured Rescan Clicking rescan will force the drivers to report the array status For any d...

Страница 38: ...ss this option is enabled Enable continue rebuilding on error default Enabled When enabled the rebuilding process will ignore bad disk sectors and continue rebuilding until completion When the rebuild...

Страница 39: ...ou can specify the amount of system resources you want to dedicate to rebuilding the array There are 5 levels of priority Lowest Low Medium High Highest Port Number default 7402 Port number that is us...

Страница 40: ...set up email alerts 1 Check the Enable Event Notification box 2 Enter the ISP server address name or SMTP name 3 Type in the email address of the sender email account that is going to send the alert 4...

Страница 41: ...text box 3 Check which type s of events will trigger an email using the respective Event Level check boxes 4 Optional Click test to confirm the settings are correct by sending out a test email 5 Click...

Страница 42: ...dministrative tasks Create delete arrays Configuring spares Rebuilding arrays Configuring event notifications Configuring maintenance Warning Alerts issued by the Host Adapter High temperatures Sector...

Страница 43: ...y The data provided on this tab helps you to anticipate any disk failures based on a variety of monitored hard disk properties To enable S M A R T monitoring go to the S M A R T section in the middle...

Страница 44: ...Task Name entry box 7 Choose how you want to schedule 8 One time verify task on specific date YYYY MM DD at HH MM SS 24 hr clock 9 Or a specific schedule you can adjust based on Daily Weekly or Monthl...

Страница 45: ...scan if the array still does not rebuild automatically 4 If the new disk is added and it does not automatically start rebuilding you can manually add the disk in maintenance a Log into the WebGUI b Cl...

Страница 46: ...d be back to Critical status Identify the correct disk and rebuild from there Online RAID Roaming One of the features of all HighPoint RAID controllers is online array roaming Information about the RA...

Страница 47: ...equires rebuilding Disabled The icon represents a disabled array meaning more than one disk failed and the array is no longer accessible Initializing The array is initializing The two types of initial...

Страница 48: ...removed or experienced failure and user needs to reinsert disk or add a new disk Rebuilding The array is currently rebuilding Verifying The array is performing a data consistency check Array status w...

Страница 49: ...Not recommended for database applications that require frequent heavy write sessions Can handle 1 disk failure Data archives and ideal for application that require data protection RAID 50 Disk Mirrori...