![High Voltage DTS-100A Скачать руководство пользователя страница 54](http://html.mh-extra.com/html/high-voltage/dts-100a/dts-100a_operators-manual_2130380054.webp)
DTS-60A / DTS-100A O
PERATORS
M
ANUAL
The data items in figure 5-2 can get the following values:
Command =
new
1. Program Name
Up to 12 characters. Do not use a space. Use ‘_’ instead.
2. Electrode Gap Value
Floating-point value that indicates the Electrode Spacing
(eg. Electrode Spacing =
2.5
+/- 0.01
mm)
3. Electrode Gap Error
Floating-point value that indicates the Electrode Spacing possible error
(eg. Electrode Spacing = 2.5 +/-
0.01
mm)
4. Electrode Gap Units
Units defined for the above values.
Options: mm or in (eg. Electrode Spacing = 2.5 +/- 0.01
mm
)
5. Electrode Type
Options: Type_I, Type_II, Type_I_II
6. Startup WAIT Timer -SWT
hh:mm:ss (hh = hours, mm = minutes, ss = seconds)
7. Startup STIRRER Timer - SST
hh:mm:ss (hh = hours, mm = minutes, ss = seconds)
8. Number of Stages
Integer value (0…29)
Command =
stage
1. Stage ID
Indicates the stage that the following information refers.
Integer value (0…29)
2. Voltage Value
Floating-point value that indicates the desired Voltage
3. Voltage Type
Options: kV/s, kV
4. Voltage Duration
hh:mm:ss (hh = hours, mm = minutes, ss = seconds)
5. Stirrer Timer- ST
The time that the stirrer will be enabled (in respect with the above timer).
hh:mm:ss (hh = hours, mm = minutes, ss = seconds)
6. After Breakdown WAIT Timer- ABDWT
hh:mm:ss (hh = hours, mm = minutes, ss = seconds)
7. After Breakdown STIRRER Timer - ABDST
hh:mm:ss (hh = hours, mm = minutes, ss = seconds)
8. After Breakdown Stage _ABDSTG
Options: integer that indicates the stage that the test will proceed after a breakdown
occurs during the current stage. The value can be 1…29 and must be greater than the
current stage id. Other possible options are the ‘next’ that indicates next stage and the
‘end’ that indicates end of the test.
Options: 1…29, next, end
9. Store Breakdown Voltage
Indicates if the breakdown voltage (if occurred) of the current stage will be calculated in
the final statistics.
Options: store or nothing
48