background image

INSTALLATION GUIDE

hidglobal.com

An ASSA ABLOY Group brand

GOVERNMENT SOLUTIONS for Physical Access

R10-H, RP10-H, R40-H, RP40-H, RK40-H, 
RPK40-H, RKCL40-P, RPKCL40-P, RKCLB40-P 

 

  

pivCLASS®  Reader

Parts

1 - Reader and base plate assembly
1 - Installation guide
2 - Terminal connector - terminal readers only

RKCL40, RPKCL40 & RKCLB40

4 - M3.5 mm x 12 mm Phillips machine screw
4 - #6-32 x .375” Phillips self-tapping machine screw
4 - #6 x 1.5” Phillips sheet metal screw
3 - #6-32 x .4375” Spanner security screw, anti-tamper (black)
3 - #6-32 x .4375 Phillips security screw (black)
1 - Mounting gasket

Recommended

•   Cable, 6 conductor, 22 or 24 AWG [65 mm or 51 mm] Twisted Pair, Over-All Shield (Belden 3108A or equivalent) - RS-485-FDX + 

power

•   Cable, 4 conductor, 22 or 24 AWG [65 mm or 51 mm] Twisted Pair, Over-All Shield and UL approved (Belden 3107A, or equivalent) - 

RS-485-HDX + power

•  Cable, 6 to 9 conductor, 22 or 24 AWG [65 mm or 51 mm] Over-All Shield, (Alpha 1296C or equivalent) - W power
•  DC power supply
•  Metal or plastic double-gang junction box - 

RPKCL40 / RPKCL40 / RKCLB40

•  Metal or plastic single-gang junction box - 

R10 / RP10 / R40 / RP40 / RK40 / RPK40

•  Reader spacer when using metal junction boxes - see pivCLASS How to Order Guide
•  Security tool (for spanner security screw, anti-tamper) HID 04-0001-03

Specifications

pivCLASS Protocol

PRODUCT

BASE PART 

NUMBER

INPUT VOLTAGE 

(VDC)

CURRENT

OPERATING 

TEMPERATURE

CABLE LENGTH

UL REF 

NUMBER

Standby 

AVG

1

Maximum 

AVG

2

PEAK

3

R10-H

900NHR

12VDC

60mA

100mA

200mA

-30° to 150° F

(-35° to 65° C)

RS-485

 = 500 ft - 22 AWG

(152 m)

300 ft - 24 AWG

(91 m)

R10E

x

1

x

2

x

3

RP10-H

900PHR

75mA

RP10E

x

1

x

2

x

3

R40-H

920NHR

65mA

110mA

R40E

x

1

x

2

x

3

RP40-H

920PHR

85mA

RP40E

x

1

x

2

x

3

RK40-H

921NHR

85mA

125mA

220mA

RK40E

x

1

x

2

x

3

RPK40-H

921PHR

95mA

RPK40E

x

1

x

2

x

3

RKCL40-P

923NPR

150mA

185mA

250mA

-4° to 122° F

(-20° to 50° C)

RKCL40E

x

1

x

2

x

3

RPKCL40-P

923PPR

RPKCL40E

x

1

x

2

x

3

RKCLB40-P

924NPR

165mA

215mA

275mA

14° to 122° F

(-10° to 50° C)

RKCLB40E

x

1

x

2

x

3

R10, RP10, R40, RK40, RP40 & RPK40

2 - M3.5 mm x 12 mm Phillips machine screw
3 - #6-32 x .375” Phillips self-tapping machine screw
2 - #6 x 1.5” Phillips sheet metal screw
1 - #6-32 x .375” Spanner security screw, anti-tamper
1 -  Mounting gasket (optional, recommended for outdoor  

installation)

1

  Standby AVG - RMS current draw without a card in the RF field.

2

 

Maximum AVG - RMS current draw during continuous PIV card reads. Not evaluated by UL.

3

  Peak - highest instantaneous current draw during RF communication. 

UL Reference Number Deciphering

x

1

  Reader Colors:

 

K = Black

x

Wiring: 

 

N = Pigtail,

 

T = Terminal

x

Communications:  N = No Module, R = RS-485 

PLT-01134 A.8

Содержание pivCLASS R10-H

Страница 1: ...Order Guide Security tool for spanner security screw anti tamper HID 04 0001 03 Specifications pivCLASS Protocol PRODUCT BASE PART NUMBER INPUT VOLTAGE VDC CURRENT OPERATING TEMPERATURE CABLE LENGTH U...

Страница 2: ...ndby AVG2 Maximum AVG3 PEAK4 R10 H 900N 5 16VDC 12VDC for RS 485 60mA 100mA 200mA 30 to 150 F 35 to 65 C Communication Lines Wiegand 500 ft 22 AWG 152 m 300 ft 24 AWG 91 m RS 485 Max bus length 4000 f...

Страница 3: ...rown P1 6 LED Input RED Pink P2 2 GPIO3 RS485 FDX Z Blue P1 7 Hold Input Gray P2 1 GPIO4 RS485 FDX Y RS 485 applicable for pivCLASS readers Tamper Output When activated output synchronizes to ground d...

Страница 4: ...names are trademarks or registered trademarks of their respective owners This Installation Guide is for informational purposes only HID makes no warranties expressed or implied in this summary Company...

Страница 5: ...40 H RP40 H RK40 H RPK40 H RKCL40 P RPKCL40 P RKCLB40 P 4 Power Testing Contactless Models Contact Models Turn on power Test card Note With a keypad reader operating as 26 bit emulation upon power up...

Страница 6: ...in this summary Company product names and data used in sample output are fictitious Specifications are subject to change without notice pivCLASS R10 H RP10 H R40 H RP40 H RK40 H RPK40 H RKCL40 P RPKCL...

Страница 7: ...the left side of the assembly 1 Disassemble the reader Remove the Keypad reader from the backplate Carefully unplug the ribbon cable from the module in the back of the Keypad reader Caution Do not pu...

Страница 8: ...ith the M2000 pivCLASS Authentication Module as well as Standard Wiegand and OSDP panels FCC Certification CAUTION Any changes or modi cations to this device not explicitly approved by manufacturer co...