9
99
During operation
Operator's Manual GB
6.4.1
6.4.1 OLP release on user panel
Press button
on the user panel whilst operating
load reducing functions. The cylinder pressure
LEDs on the user panel perform a running light.
The LED for padlock symbol will blink red.
6.4.2 OLP release on controller
XSDrive
Press and hold the button
on the controller
whilst operating load reducing functions. On the
user panel the cylinder pressure LEDs perform a
running light. The LED for padlock symbol will
blink red.
6.4.3 OLP release on controller Com-
biDrive
Press the button
⑨
on the right hand side below
the display handle. The unlocked padlock will
appear in the centre display. On the user panel
the cylinder pressure LEDs perform a running
light. The LED for padlock symbol will blink red.
6.5
Manual extensions [option]
Operation with manual extensions
• Always extend the hydraulic extensions first,
then the manual extensions.
• The use of manual extensions should be
restricted to the longest outreach needed.
When this reach is not needed, the manual
extension should be retracted.
DANGER
Do not stand in front of moving parts. They
may eventually move and cause injuries.