PRINCIPLES OF OPERATION 19
AQUATECH OPERATIONS, SERVICE AND PARTS MANUAL
A Product of Hi-Vac Corporation
PRINCIPLES OF OPERATION
LEAVING THE WORK SITE:
1. Before leaving the worksite for the dumpsite, assure the boom is in its travel position
and properly latched.
2. Proceed to dumpsite.
DUMPING THE DEBRIS TANK:
Caution!
When dumping this vehicle, always seek firm, level terrain on which to park the vehicle when
setting up to dump. Never lift the tank when the unit is parked on a grade, or when the
underlying ground is soft or unstable. Failure to follow these guidelines may result in a
catastrophic accident in which the vehicle may tip over or the tank may shear from its mounting
supports.
Do not attempt to raise the tank until the door has been opened to allow the debris to empty.
Never drive this vehicle with the tank raised or the tank door opened.
Be sure the area above the vehicle is free of electrical lines or any other obstructions.
1. Position the truck at the dump site, set the parking brake, and block the wheels.
2. Procedure for opening the rear door and raising the tank:
Note:
Maximum operating speed for opening the rear door is 1500 RPM.
a.
Disengage the rear axles.
b.
Rotate the boom to the rear.
c.
Your unit is equipped with hydraulic door locks, push and hold the toggle switch
marked LOCKS upward to unlock the hydraulic door locks.
d.
Raise the door with the toggle switch marked DOOR located on the side control panel.
Push the switch up and hold until the door is completely open.
e.
Push the switch up and hold to raise the debris tank as needed to
allow the debris to completely dump out of the tank.
f.
After dumping is complete, pushi the switch and hold down until
the tank is completely down on the sub frame.
g.
Close the door by pushing the toggle switch marked DOOR. If your unit is equipped
with hydraulic door locks, lock the door by pushing the toggle switch marked LOCKS
and holding until the locks are completely closed.
h.
Next, open the gate valve located at the bottom of the hopper mounted below the
cyclone separator. Allow debris to drain. Close the gate valve.
i.
Open and clean the exhauster final filter.
Note:
Make sure that the door is completely closed prior to closing the hydraulic locks.
Содержание X-Vac Hydro Excavator X15 Series
Страница 6: ......
Страница 8: ......
Страница 46: ......
Страница 51: ...CONTROLS 3 AQUATECH OPERATIONS SERVICE AND PARTS MANUAL A Product of Hi Vac Corporation CONTROLS ...
Страница 53: ...CONTROLS 5 AQUATECH OPERATIONS SERVICE AND PARTS MANUAL A Product of Hi Vac Corporation CONTROLS ...
Страница 55: ...CONTROLS 7 AQUATECH OPERATIONS SERVICE AND PARTS MANUAL A Product of Hi Vac Corporation CONTROLS ...
Страница 64: ...WATER SYSTEM WATER SYSTEM 4 AQUATECH OPERATIONS SERVICE AND PARTS MANUAL A Product of Hi Vac Corporation ...