![Hi-Target HTS-420R Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/hi-target/hts-420r/hts-420r_manual_2128991028.webp)
Total Station Manual
-
27 -
Steps
Key
Display
○
1 After entering to the
interface of EDM Setting,using
the direction of
↓
to move
the cursor to the setting item
of P.C.
↓
[EDM Setting]
EDM Mode: Single
Reflector: Prism
P.C. :
OK
30.0 mm
ATOMS Pointer
○
2 Enter the prism constant
value and press the key of
[ENT].
※
1
※
2
[ENT]
[EDM Setting]
EDM Mode: Single
Reflector: Prism
P.C. :
OK
-30.0 mm
ATOMS Pointer
○
3
After finished setting,
press [F3](OK) to return the
function of Q-Surveying.If you
want to cancel the settings,
press [ESC] to ignore the
changes.
[F3]
1
ALL
Code
EDM
[Q-Survey] 1/3
Pt. :
T.H. :
Code :
HA :
VA :
:
1.500 m
13°29′59″
90°59′23″
※
1
:
Prism constant you enter is effective only when the reflector mode isPrism.
※
2
:
The range of Prism constant value
:
-99mm
~
+99mm.
2.2
Atomosphere setting
Refraction
:
When measuring horizontal distance and elevation, our instrument corrects the
atmospheric refraction and the earth curvature automatically.
The instrument supports of atmospheric refraction coefficient have three option,
they are 0.00, 0.14, and 0.20.
Note:
The refraction of instrument has been set for K=0.00 when left factory .It also
can be set to other values