Q7:
In auto-work mode,data sent to the module through serial will delay
sometime to send to the network,why?
A: In auto-work mode,framing and sending data has two trigger qualification:trigger time
and trigger length,if the length of data doesn’t reach the trigger length,and it will wait to be
framed and sent coercively after trigger time,the specific is refered in Section 4.2.2.2.
26B30B30B30B
Q8:
In auto-work mode,why does the module not exit the transmission state,
after inputing the escape character?
A: To exit transparent transmission has strict limits.You should wait for at least 5s then send
the escaple character.If wpa/wpa2,it will take about 15s.
27B32B32B32B
Q9:
To modify the parameters with configuration program,why does it show
the error ’used prohibitive operating symbol’?
A: Please disconnect the network connection first,and then refer the modified parameters.
28B33B33B33B
Q10:
Why can not web pages of the WEB server open?
A
:
The reasons maybe include,
whether the WEB server is forbided
Whether the server port is set correctly or not, if the port is set to the number except
80,then it’s needed to input the port number in the address bar while using a browser, such
as http://192.168.1.100:2000.
29B34B34B34B
Q11:
When user sets the serial to the paud rate it does not support, the
module can’t be connected to, then how to correct it ?
A
:
Resume it to the manufacturer setting,the approachs is as follow,