Hi-Force TWE Series Скачать руководство пользователя страница 9

 

OPERATING INSTRUCTIONS: 

Electric Torque Wrench 

Series: TWE 

TDS:- 

1399 

Prepared by:-  M.DAVIES 

Approved by:- 

 

Date: 25/03/14 

REV NO:- 

 

 

 

 

ECO:-  

 

 

 

 

 

 

Page 

9

 of 

20

 

 

3.1.2

 

Measure selection 

As soon as the tool is switched on, the 
operator can see the factory settings in 
Nm and lbf.ft.  
The user can’t see this when Poti-
setting is selected. 

 

     
 

3.1.3

 

Gear selection 

The engaged gear is illuminated on the 
display: 
 

Gear 2 
Gear 1 

 

 

3.1.4 TORQUE SETTINGS 

The torque setting can be made in two different ways:  
 

 

1.0

 

Torque setting with poti setting 

Select the required torque from the chart fixed 
to the motor housing and adjust the knurl to 
those values. 
The poti setting is displayed with one post-
decimal place on the display. 
e.g. 3,2 

 

This is a factory default setting. 

 

 

2.0

 

Torque setting in clear 

The display shows the torque in Nm or lbf.ft. 
The intervals of the torque setting are 
dependent on the rotational speed of the poti 
wheel. 

 

 

 

 

Torque setting on the display 
(valid for both) 

Turn the torque setting dial 

(2)

 to the required 

value. 
After the torque setting dial is stopped, the set 
value will flash. 
Press the enter button to set this value. If this does 
not happen within 3 seconds the value will not be 
set and the original value will remain. 
The original value also remains after the tool is 
switched off. 

 

 

 

Содержание TWE Series

Страница 1: ...RATING INSTRUCTIONS Hi FORCE SERIES TWE Electric Torque Wrench These instructions are issued to ensure safe operation of the tool by the intended Operator To ensure maximum safety a copy of these inst...

Страница 2: ...3 OPERATING PARAMETERS 5 1 4 EMISSIONS 5 1 5 RISK ASSESSMENT 5 1 6 ELECTRICAL SAFETY 7 1 7 OPERATOR 7 2 TECHNICAL DATA 7 3 OPERATION 7 3 1 GENERAL INFORMATION 7 3 2 TORQUE ANGLE MODE OPTIONAL 11 3 3 I...

Страница 3: ...h the equipment under load Be aware Distraction can cause you to lose control of the power tool Personal Safety Before commencing work with this equipment the operator should wear all the personal pro...

Страница 4: ...be switched on or off easily is dangerous must be withdrawn from use and must be repaired by a qualified technician Do let any unauthorized personnel use the power tool Electric power tools are danger...

Страница 5: ...thout prior written permission from Hi Force will be deemed as improper use and all warranty and guarantees on the tool are declared invalid The wrench must not be used in an atmosphere where explosio...

Страница 6: ...Other hazards A risk of crushing between the pistol grip and surrounding components The pistol grip and or driving unit are able to rotate The impact socket and the support arm can become detached if...

Страница 7: ...caring out any work on the electric unit remove the plug from the mains supply 1 7 OPERATOR Minimum age 18 years The operator must carefully read and understand the operating manual before using the t...

Страница 8: ...otor and gear are rotating it is not possible to make a setting on the display Also the on off switch and left right switch are closed down Classification Construction size Slow Strong Mode Fast Mode...

Страница 9: ...e from the chart fixed to the motor housing and adjust the knurl to those values The poti setting is displayed with one post decimal place on the display e g 3 2 This is a factory default setting 2 0...

Страница 10: ...gear control knob 9 in position 2 Only change gear when the motor is NOT running Should the speed selector not engage properly operate the torque wrench for a short time with no load applied 3 1 7 FA...

Страница 11: ...ction including the symbol to flash three times Then the selected mode is engaged ATTENTION Angle of tilt mode selection is only possible in gear 1 mode If this selection is attempted in gear 2 mode a...

Страница 12: ...ate the on off switch to start the bolting process with the application of the snugging torque Apply the torque at slow motor speed in order to keep the dynamic forces low When the snugging torque is...

Страница 13: ...n Then the motor increases in speed If the required torque is too high for the tool the process stops The display shows for 3 seconds OLOAD OVERLOAD Additionally an acoustic warning signal sounds The...

Страница 14: ...age Err03 flashes in the display for 3 seconds Bolting process is interrupted Additionally an acoustic warning signal emits The two diode lights flash red alternately The message is documented 3 4 3 D...

Страница 15: ...ed Additionally an acoustic warning signal is emitted The two diode lights flash red alternately The error is documented Remedy Unplug the tool and plug in again If the error is still present send dev...

Страница 16: ...ning procedure turn the reaction arm 13 slowly towards the abutment by starting the motor If necessary start motor at intervals Make sure the reaction arm is tightly fitted against the abutment The re...

Страница 17: ...been tightened to the required torque must not be tightened again with the same torque This will lead to excess torque being applied At normal operating temperature and with constant mains voltage the...

Страница 18: ...intervals in order to safeguard the electrical safety Before use always check that the fixing bolts of the pivoting handles sit tightly and that the handle itself is intact After gears have been run...

Страница 19: ...OPERATING INSTRUCTIONS Electric Torque Wrench Series TWE TDS 1399 Prepared by M DAVIES Approved by Date 25 03 14 REV NO 1 ECO Page 19 of 20 1 2 3 4 5 6 7 8 9 13...

Страница 20: ...Tel 994 12 447 4100 Email baku hi force com Hi Force Hydraulics Asia S B Selangor Malaysia Tel 603 5569 4209 Email malaysia hi force com Hi Force Nederland BV Strijen Netherlands Tel 31 78 6745488 Ema...

Отзывы: