IMPORTANT DECLARATIONS 

 

Copyright © 2018 Heyuan Intelligence Technology Co., Ltd All Rights Reserved  
 
This manual may not be reproduced, copied, transmitted or transcribed in whole or in part 
by  any  means  without  the  expressed  written  permission  of  Heyuan.  Any  shall  be 
investigated  for  legal  responsibility  in  violation  of  copyright  or  other  intellectual  property 
rights  of  the  Company.  We  check  the  user  manual’s  contents  regularly  and  will  make 
necessary  amendments  in  next  version.  Welcome  to  give  advice  for  some  unexpected 
errors. The rights of upgrading without notice are reserved. 
 
Please  read  this  manual  carefully  before  the  product  is  operated.  And  once  you  start 
operating the meter, you’ll be considered to have read this manual and accept all our terms. 
Heyuan shall not be responsible or liable for any damages or injuries caused by improper 
meter installation and/or operation. 
 
Attention: the following symbols in this manual refer to meanings as follows  

   

Electric  Shock  Symbol:  Carries  information  about  procedures  which  must  be 

followed to reduce the risk of electric shock and danger to personal health   

    

Safety  Alert  Symbol:  Carries  information  about  circumstances  which  if  not 

considered may result in injury or death 
 

The  meter  must  be  installed  and  operated  by  one  who  has  experience  with  high-voltage 
devices or has qualifications. Please connect the meter to correct voltage before operating 
the meter. Please install and use the meter according to the user manual. Heyuan shall not 
be  responsible  or  liable  for  any  damages  or  injuries  caused  without  following  the 
instructions in the user manual. 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание DZ81-MS3UI5C

Страница 1: ...DZ81 MS3UI5C Energy Meter User Manual V1 0 Heyuan Intelligence Technology Co Ltd...

Страница 2: ...ered to have read this manual and accept all our terms Heyuan shall not be responsible or liable for any damages or injuries caused by improper meter installation and or operation Attention the follow...

Страница 3: ...ifications 1 2 1 Dimension 1 2 2 Installation 1 2 3 Technical Parameters 1 2 4 Wiring 2 Chapter 3 Meter Display and Basic Operation 6 3 1 Parameters Display 6 3 2 Parameters Setting Operation 8 Chapte...

Страница 4: ...metering 2 31 times harmonic analysis Display LCD Chapter 2 Specifications 2 1 Dimension unit mm Cut Out Size Unit mm Side View Unit mm 2 2 Installation unit mm This series of products should be inst...

Страница 5: ...d Overload 1 2 times of the rated value Momentary Overload 2 times of the rated value Frequency 45 60Hz Functional Module Pulse output 1 Interface 1 RS485 Modbus communication protocol Baud rate 1200...

Страница 6: ...ld be set as 2LL and the IL the current wiring mode should be set as 2C at the parameter setting interface 2 4 2 Power supply communication interface and Digital input A Power Supply The power supply...

Страница 7: ...al number of digital input depends on the actual energy meter model Chapter 3 Meter Display and Basic Operation There are four buttons on the front panel labeled H P E and V A from left to right It ca...

Страница 8: ...ine voltage and current circularly 2 Press button E it will display the values of energy parameters circularly Total Active Energy Total Reactive Energy 3 Press button P it will display the values of...

Страница 9: ...nterface of metering data it will enter the system setting interface At the setting mode The button H is used for digital shift It can edit one digit shift left each time and the digit will be flashin...

Страница 10: ...r the next setting interface Password Input Interfaces 2 Back light Time Setting BL interface is the page of backlight time setting At this page the user can see and set the backlight time the setting...

Страница 11: ...ree Line open delta connection After the setting please press V A to confirm and enter the next setting interface Voltage Wiring Mode 6 Current Connection Method Setting IL is the current wiring mode...

Страница 12: ...y is responsible for free maintenance or exchange within three year warranty period 3 The cost of the components and freight shall be charged for improper meter installation and or operation 4 Over th...

Отзывы: