8. Troubleshooting
WARNING: All maintenance work listed below must be carried out with the device switched off, i.e.
with the mains plug pulled out.
PROBLEM
CAUSE
Model
Solution
Device does not start
No voltage on the device
Switch not turned on
B
B
Connect the device to the socket; check
whether current is running through it. Turn
switch on
Compressor does not start
The device takes 5 minutes to
re-start.
Overload prevents start.
Defective or broken conductor.
Defective relay.
Compressor does not run.
Device is being thawed.
B
B
HS
HS
HS
Switch off device, wait 5 minutes, then
start.
Reduce room temperature to below 38°C.
Replace or repair broken/loose conductor.
Check relay with volt/ampere metre.
Contact your dealer or the HEYLO service
centre.
Wait for approx. 15 min.
(Display indicates “de-frosting“)
Fan is not running
Fan blocked
Loose or broken conductor
Defective fan motor
B
HS
HS
Remove blockage
Replace broken conductor
Change fan motor
De-humidifier functions,
but room does not get dry
Not enough time to dry out
Lack of air movement
Too much inflow of (external)
air
B
B
B
Take more time to dry out
Increase air movement with HEYLO turbo
dryers
Reduce air flow in the areas to be dried.
Ice or moisture only on
one part of the cooling line
System is possibly leaking
System is not filled enough
HS
HS
Look for leaking spot with a gas tracking
device.
Repair and re-fill system.
No moisture or ice on the
cooling lines
Temperature or air humidity
too low
System is possibly leaking
Cooling system damaged
Compressor is not running
B
HS
HS
HS
Measure surrounding atmosphere with
HEYLO MMS plus
Look for leaking spot with a gas tracking
device
Check compressor
Contact your dealer or the HEYLO service
centre
Device continuously on de-
frosting (ER4)
Room temperature is too low
Defective regulator
B
HS
Increase room temperature.
Change evaporator sensor
Device does not de-frost
Defective thawing device
Defective regulator
HS
HS
Change magnetic valve or coil
Change evaporator sensor
Device collects little water
Room is too dry
Room temperature is too low
Air flow restricted by device
B
B
B
Determine air humidity with a hygrometer.
Increase room temperature.
Increase air flow, clean filters and lines.
Device does not pump off
(ER09)
Check pump for possible
defects
Defective pump
Condensate hose blocked or
bent
HS
HS
B
Clean pump and change defective parts if
necessary
Change pump
Clean condensate hose
Column 3: B – User, HS – HEYLO Service