4.
Assemble the outer rails:
a.
Attach the left outer rail and the right outer rail to the rear mounting brackets using two
1/4-20 hex nuts with captive star lock washers attached loosely, as shown in
. Do not tighten the nuts.
Figure 16 Installing the outer rails (HPE 10000 Series rack)
b.
Depending on the rack you are using, complete one of the following tasks:
•
For an HPE 10000 Series Rack, install two #10-32 x 1/2-inch Phillips panhead
screws with captive star lock washers and two #10 adapter washers in the upper
and lower holes on the right rail. Then, install two #10-32 x 1/2-inch Phillips panhead
screws with captive star lock washers and two #10 adapter washers in the upper
and lower holes on the left rail. (See
.)
Figure 17 Assembling the outer rails (HPE 10000 Series rack)
•
For an HPE System/e Rack, install two #10-32 x 1/2-inch Phillips panhead screws
with captive star lock washers and two #10 alignment washers in the upper and
lower holes on the right rail. Then, install two #10-32 x 1/2-inch Phillips panhead
screws with captive star lock washers and two #10 alignment washers in the upper
and lower holes on the left rail. (See
.)
Figure 18 Assembling the outer rails (HPE System/e rack)
Installing the switch using the SAN Switch Rack Mount Kit
33