Hewlett Packard Enterprise StorageWorks 1606 Extension Power Pack+ SAN Switch Скачать руководство пользователя страница 1

HPE StorageWorks
8-Gb SAN Switch

Hardware Reference Guide

Abstract

This document provides information on installing, configuring, and maintaining the 8-Gb SAN family of HPE StorageWorks
Fibre Channel switches. This document is intended for system administrators and technicians with knowledge of SANs and
HPE StorageWorks Fibre Channel switches.

Part Number: 5200-1457
Published: June 2016
Edition: 6

Содержание StorageWorks 1606 Extension Power Pack+ SAN Switch

Страница 1: ...tion on installing configuring and maintaining the 8 Gb SAN family of HPE StorageWorks Fibre Channel switches This document is intended for system administrators and technicians with knowledge of SANs...

Страница 2: ...ained herein is subject to change without notice The only warranties for Hewlett Packard Enterprise products and services are set forth in the express warranty statements accompanying such products an...

Страница 3: ...Feature comparison of base and upgraded products 17 Available licenses 18 Port side of the 1606 Extension SAN Switch 19 Nonport side of the 1606 Extension SAN Switch 19 Installing and activating Port...

Страница 4: ...51 8 80 SAN Switch LEDs 52 Port side LED activity for the 8 80 SAN Switch 53 Nonport side LED activity for the 8 80 SAN Switch 54 Port side LED activity for the Encryption SAN Switch 55 Port side LED...

Страница 5: ...ns Commission notice for Class A equipment 84 Modifications 84 Cables 84 Regulatory compliance identification numbers 84 Laser device 84 Laser safety warning 84 Certification and classification inform...

Страница 6: ...rtuguese notice 90 Slovakian notice 91 Slovenian notice 91 Spanish notice 91 Swedish notice 91 B Electrostatic discharge 93 How to prevent electrostatic discharge 93 Grounding methods 93 Glossary 94 I...

Страница 7: ...4 SAN Switch Ships with 16 ports activated and includes a Full Fabric license It includes Advanced Web Tools Advanced Zoning and EGM as standard software components HPE StorageWorks 8 40 SAN Switch Sh...

Страница 8: ...itch Power Pack models ship with the following licensed options Adaptive Networking Fabric Watch APM Extended Fabric ISL Trunking Server Application Optimization NOTE The HPE StorageWorks 2408 FCoE Po...

Страница 9: ...e and exhausting to the port side Activating additional 8 8 and 8 24 SAN Switch ports By default the 8 8 SAN Switch model integrates eight licensed ports ports 0 through 7 Additionally the 8 24 SAN Sw...

Страница 10: ...n a dedicated routing blade or switch Just like traditional FCR IR uses EX_Ports to import and export devices between fabrics enabling selective device sharing while maintaining remote fabric isolatio...

Страница 11: ...8 RISC CPU running at 1 3 GHz with integrated peripherals that provides high performance with low power consumption Ships FICON and FICON Cascading ready FICON CUP is available but requires an optiona...

Страница 12: ...s 48 55 5 Ethernet port 14 FC ports 56 63 6 USB port 15 FC ports 64 71 7 FC ports 0 7 16 FC ports 72 79 8 FC ports 8 15 Nonport side of the 8 80 SAN Switch and the Encryption SAN Switch Figure 5 page...

Страница 13: ...features The Encryption SAN Switch has the following features 32 front end 1 2 4 or 8 Gb s autosensing F_Port FL_Port E_Port EX_Port or M_Ports to connect host servers SAN disks SAN tapes edge switche...

Страница 14: ...of 4 Gb s SFPs 1 2 and 4 Gb s and 8 Gb s SFP 2 4 and 8 Gb s Fabric OS support delivering distributed intelligence throughout the network and enabling a wide range of applications including Web Tools a...

Страница 15: ...iguration to provide hardware redundant cooling Includes universal ports that self configure as E_Ports F_Ports M_Ports or FL_Ports Provides extensive diagnostics and system monitoring capabilities fo...

Страница 16: ...upply 1 2 Fan assembly 3 3 Fan assembly 2 1606 Extension SAN Switch features A fully licensed 1606 Extension SAN Switch has the following features FCIP capability Includes up to eight FCIP tunnels Eac...

Страница 17: ...and ge1 can be configured for use with either copper or optical cables Rack mountable 1U chassis Two PowerPC 440EPx processors running at 667 MHz One GoldenEye2 switch ASIC for 1 2 4 or 8 Gb s FC swit...

Страница 18: ...s are provided FC frame compression is not the same as IP compression and is disabled by default To enable FC frame compression use the portCfg command For more information see the Fabric OS Administr...

Страница 19: ...agement port 5 USB port The Fibre Channel ports are numbered from left to right on the faceplate as shown in Figure 10 page 19 Figure 10 Port numbering on the 1606 Extension SAN Switch 3 GbE ports ge0...

Страница 20: ...se a Log in to the switch as admin b Issue the licenseadd command followed by the license key enclosed in quotation marks The license key consists of approximately 16 uppercase and lowercase letters a...

Страница 21: ...tor s Guide for the firmware version you are running Supported SFP transceiver options Table 2 page 21 lists the only SFPs supported in your HPE StorageWorks 8 Gb SAN Switches Table 2 Supported SFP tr...

Страница 22: ...on these products is include in the product QuickSpecs which can be accessed from the Hewlett Packard Enterprise website http h18006 www1 hp com storage networking b_switches san index html HPE Stora...

Страница 23: ...1692 B23 15 m LC to LC multi mode FC cable 221692 B26 30 m LC to LC multi mode FC cable 221692 B27 50 m LC to LC multi mode FC cable OM3 LC LC type cables AJ833A 0 5 m LC LC multi mode OM3 FC cable AJ...

Страница 24: ...an 8 Gb SAN Switch Shipping carton contents Figure 13 page 24 and Table 4 page 25 identify shipping carton contents for a typical 8 Gb SAN Switch The shipping configuration for your model can vary Fig...

Страница 25: ...assemblies Two rear mounting brackets A right inner rail and a right outer rail A left inner rail and a left outer rail One 8 Gb SAN Switch including power supply and fan assembly units Installation a...

Страница 26: ...und at all times Do not rely on a secondary connection to a branch circuit such as a power strip Ensure that airflow and temperature requirements are met on an ongoing basis particularly if the switch...

Страница 27: ...1 Unpack the switch and verify that all items listed in Shipping carton contents page 24 are present 2 Locate the four rubber feet in the accessory box 3 Apply the adhesive rubber feet to the switch...

Страница 28: ...N Switch 1606 Extension SAN Switch FCoE Converged Network Switch Encryption SAN Switch Multiprotocol MP Router 400 Multiprotocol MP Router Related documentation For the latest B series switch product...

Страница 29: ...at least 68 6 cm 23 inches deep For the MP Router 4 64 SAN Switch or 8 80 SAN Switch and Encryption SAN Switch plan a rack space that is at least 2 units high Ground all equipment in the rack through...

Страница 30: ...h wrench or socket Plenum if required See Before you begin Important information about the plenum page 28 to determine whether you need to install a plenum before rack mounting your device SAN Switch...

Страница 31: ...k This allows air to enter the front of the rack and exit from the rear To install the device in a rack 1 Verify that the required parts and hardware are available See Table 5 page 30 2 Choose a mount...

Страница 32: ...15 Installing the rear mounting brackets HPE System e rack NOTE The SAN Switch Rack Mount Kit contains rails labeled Left and Right to designate the left side and right side of the cabinet as viewed f...

Страница 33: ...the right rail Then install two 10 32 x 1 2 inch Phillips panhead screws with captive star lock washers and two 10 adapter washers in the upper and lower holes on the left rail See Figure 17 page 33 F...

Страница 34: ...4 8 SAN Switch 4 16 SAN Switch SAN Switch 4 32 N A Six three per rail 4 32B SAN Switch N A Six three per rail MP Router N A Ten five per rail 4 64 SAN Switch 400 MP Router N A Ten five per rail 8 8 SA...

Страница 35: ...the SAN Switch 2 16V or SAN Switch 2 16N 7 Secure the two inner rails one on each side to the device using the appropriate number of screws see Table 6 page 34 For example Figure 19 page 35 shows an...

Страница 36: ...to the 4 8 or 4 16 SAN Switch but this procedure also applies to other switch models that require a plenum Figure 21 Attaching the plenum to a 4 8 or 4 16 SAN Switch 3 Two screws that secure the rails...

Страница 37: ...switch HPE 9000 Series or HPE 10000 Series racks Figure 23 Securing the device in an HPE System e Rack 3 Tighten the hex nuts installed in of Page 30 See Page 33 This completes the rack mount procedur...

Страница 38: ...one power cord The 8 40 and 8 80 SAN Switches Encryption SAN Switch FCoE Converged Network Switch and 1606 Extension SAN Switch use two power cords IMPORTANT The 8 8 and 8 24 SAN Switches do not have...

Страница 39: ...the RJ 45 serial port on the workstation Figure 24 Connecting the serial cable 2 Close any serial communication programs running on the workstation 3 Open a terminal emulator application such as Hyper...

Страница 40: ...HCP OFF off 5 Optional Verify that the address is correct by issuing the ipaddrshow command at the prompt 6 Record the IP address on the label located on the port side of the chassis Record the IP add...

Страница 41: ...nable the switch by entering the switchenable command Setting the switch date and time The 8 Gb SAN Switch maintains the current date and time inside a battery backed RTC circuit Switch operation does...

Страница 42: ...e settings persist across failover for high availability Setting the time zone IMPORTANT The following procedure describes how to set the time zone for a switch You must perform the procedure on all s...

Страница 43: ...tstimezone parameter difference from UTC Local time 4 0 Atlantic Standard 3 0 Atlantic Daylight 5 0 Eastern Standard 4 0 Eastern Daylight 6 0 Central Standard 5 0 Central Daylight 7 0 Mountain Standa...

Страница 44: ...For more information on using an NTP server and IPv6 considerations see the Fabric OS Administrator s Guide 44 Installing and configuring an 8 Gb SAN Switch...

Страница 45: ...one NTP server using a DNS name switch admin tsclockserver 10 32 170 1 10 32 170 2 ntp localdomain net Updating Clock Server configuration done Updated with the NTP servers Changes to the clock serve...

Страница 46: ...tch name 1 Using Telnet log in to the switch as admin 2 Use the chassisname command to change the chassis name The following example shows how to change the chassis name to myhpchassis switch admin ch...

Страница 47: ...E Secure Key Manager User Guide If the Encryption SAN Switch is being configured for the first time for encryption services you must perform the following pre initialization tasks related to configuri...

Страница 48: ...ally the FC ports on the 1606 Extension SAN Switch are set to persistently disabled If you want to enable the FC ports as standard E_Ports or F_Ports use the portcfgpersistentenable command If you are...

Страница 49: ...C 2 2 dc0200 id N8 No_Light FC 3 3 dc0300 id N8 No_Light FC 4 4 dc0400 N8 No_Module FC 5 5 dc0500 N8 No_Module FC 6 6 dc0600 N8 No_Module FC 7 7 dc0700 N8 No_Module FC 8 8 dc0800 id N8 No_Light FC 9 9...

Страница 50: ...ashing light The LEDs are either green or amber 8 8 and 8 24 SAN Switch LEDs 8 8 and 8 24 SAN Switch LEDs are located on the port side only Figure 26 Identifying 8 8 and 8 24 SAN Switch LEDs 4 Link sp...

Страница 51: ...gure 28 page 51 Figure 27 Identifying 8 40 SAN Switch port side LEDs 1 System status LED top and system power bottom 2 Ethernet port status LEDs green amber 3 FC port status port 9 Figure 28 Identifyi...

Страница 52: ...0 SAN Switch port side LEDs 8 FC ports 0 through 7 1 8 80 SAN Switch 9 FC ports 48 through 55 2 System status LED 10 FC port status LED port 52 3 Ethernet port 11 FC port status LED port 48 4 Ethernet...

Страница 53: ...reen Verify that the system is on and has completed booting System is off or there is no power No light System status No action required System is on and functioning properly Steady green Verify that...

Страница 54: ...t running Re enable the port using the portenable command Port is disabled because of diagnostics or the portdisable command Slow flashing amber flashing in 2 second intervals Check the management int...

Страница 55: ...cryption SAN Switch and FRU LEDs Recommended action Status of hardware LED color LED name No action required System is on and functioning properly No light System status Attention Do the following Ind...

Страница 56: ...4 second then off 1 4 second No action required Port is online and frames are flowing through the port Flickering green No action required Port is receiving light or signal carrier but is not online...

Страница 57: ...Fan FRU is not seated correctly One or more of the fans in the fan FRU has failed Verify that the fan FRU is enabled use the fanenable command The fan FRU was disabled by the user Replace the fan FRU...

Страница 58: ...r log for details on the cause Attention is required Several variables can cause this status Flashing amber of the status Contact your switch service provider including a power supply failure fan fail...

Страница 59: ...n 1 2 second No action required Online frames flowing through port Flickering green Nonport side LED activity for the FCoE Converged Network Switch Figure 32 page 59 shows the LEDs on the nonport side...

Страница 60: ...wered on No action required Fan assembly is operating normally Steady green Do the following Fan fault for one of the following reasons Steady amber for more than 5 seconds Verify the fan FRU is enabl...

Страница 61: ...ribes the port side LEDs and the recommended actions Table 13 1606 Extension SAN Switch port side LED patterns Recommended action Status of hardware LED color LED name Verify the following System is o...

Страница 62: ...ed There is link activity traffic Flashing green Verify that the power LED is on Verify the SFP and cable Indicates one of the following No light FC port status No signal or light carrier media or cab...

Страница 63: ...or repair Nonport side LED activity for the 1606 Extension SAN Switch The LEDs on the nonport side of the 1606 Extension SAN Switch are shown in Figure 11 page 20 Table 14 page 63 describes the nonpor...

Страница 64: ...are using Web Tools errors are listed under Switch Events If you are using the CLI errors detected during POST are written to the system log which is viewed using the errshow command For more informat...

Страница 65: ...orarily lock the transmit and receive speed of the links during diagnostic testing For information about specific diagnostic tests see the Brocade Fabric OS Troubleshooting and Diagnostics Guide Insta...

Страница 66: ...To determine whether a fan assembly should be replaced do any of the following Check the system status LED Figure 35 page 66 If the fan status LED is not on verify that the fan is seated correctly If...

Страница 67: ...oximately two minutes You will need New power supply and fan assembly FRU one unit Phillips head screwdriver 1 To replace the power supply and fan assembly unit 1 Use a Phillips head screwdriver to un...

Страница 68: ...n the switch until it can be replaced Maintain all three fan assemblies in operational condition to provide redundancy Replacing the 8 80 SAN Switch and Encryption SAN Switch fan assembly Replacing a...

Страница 69: ...o indicate normal operation see Table 15 page 67 5 Optional Display the fan status using the fanshow command from the CLI see Figure 37 page 69 for the locations of Fan assembly 1 Fan assembly 2 and F...

Страница 70: ...y powered off press the AC power switch to power it off 3 Unplug the power cord from the power supply you are replacing Figure 38 Installing a power supply in the 8 80 or Encryption SAN Switch 4 Capti...

Страница 71: ...S identifies the power supplies as follows viewing the switch from the port side Power supply 1 is on the left Power supply 2 is on the right To determine whether a power supply should be replaced do...

Страница 72: ...ch IP over FC Ethernet or serial connection Fabric Manager optional For information see the Fabric Manager User s Guide NOTE The Fabric Manager does not manage the Encryption SAN Switch or FCoE Networ...

Страница 73: ...nl 42 9 cm nl 42 88 cm nl Width 17 inches 16 8 inches 16 88 inches 16 8 inches 16 88 inches 16 887 inches 64 14 cm nl 63 4 cm nl 63 5 cm nl 61 cm nl 61 cm nl 30 6 cm nl Depth 25 25 inches 25 inches 2...

Страница 74: ...e 8 8 8 24 8 80 Encryption and 1606 Extension SAN Switches Primary AC input 100 240 VAC 2 0 A 47 63 Hz switch autosenses input voltage Electrical 8 40 SAN Switch Primary AC input 90 264 VAC switch aut...

Страница 75: ...munity EN55022 or CISPR22 or AS NZS CISPR22 Australia New Zealand IEC60950 1 or latest Argentina 51318 22 99 and 51318 24 99 IEC60950 1 or latest Russian Federation KN22 and KN24 Korea GB17625 1 2003...

Страница 76: ...k Switch 1 044 11 BTU hr 1606 Extension SAN Switch 590 BTU hr 8 8 and 8 24 SAN Switches 21 5 A at 240 VAC cold start In rush current 8 40 SAN Switch 15 35 A maximum 8 80 SAN Switch 15 A maximum for pe...

Страница 77: ...out an HPE Extended Fabrics license N A 9 50 to 100 km with an HPE Extended Fabrics license N A N A 150 m 492 ft 50 4 Gb s N A N A 70 m 230 ft 62 5 N A N A N A 9 N A N A 150 m 50 8 Gb s N A N A 21 m 6...

Страница 78: ...Switch Long wavelength FCoE Converged Network Switch Long wavelength Encryption SAN Switch Short wavelength Cable size nl microns Port speed N A N A 500 m 1 640 ft OM2 860 m 2 821 ft OM3 50 1 Gb s N...

Страница 79: ...the 1606 Extension SAN Switch Long wavelength Short wavelength Cable size nl Port speed microns N A 500 m 1 640 ft OM2 860 m 2 821 ft OM3 50 1 Gb s N A 300 m 984 ft 62 5 4 km 2 48 miles N A 9 FCoE Co...

Страница 80: ...diagnostics Initializes the operating system Initializes the hardware Runs diagnostic tests on several functions including circuitry port functionality memory statistics counters and serialization Boo...

Страница 81: ...k To make comments and suggestions about product documentation please send a message to storagedocsFeedback hp com All submissions become the property of HP Related information The following documents...

Страница 82: ...protects personnel and equipment WARNING To reduce the risk of personal injury or damage to equipment Extend leveling jacks to the floor Ensure that the full weight of the rack rests on the leveling j...

Страница 83: ...failure to follow directions could result in bodily harm or death CAUTION Indicates that failure to follow directions could result in damage to equipment or data IMPORTANT Provides clarifying informa...

Страница 84: ...this device must be made with shielded cables with metallic RFI EMI connector hoods in order to maintain compliance with FCC Rules and Regulations Regulatory compliance identification numbers For the...

Страница 85: ...in Figure 39 page 85 or equivalent may be located on the surface of the Hewlett Packard Enterprise supplied laser device Figure 39 Class 1 laser product label This optional label indicates that the p...

Страница 86: ...an alkaline battery pack There is risk of fire and burns if the battery pack is not properly handled To reduce the risk of personal injury Do not attempt to recharge the battery Do not expose to tempe...

Страница 87: ...st them Pay particular attention to the plug electrical outlet and the point where the cords exit from the product Japanese power cord statement Waste Electrical and Electronic Equipment directive Eng...

Страница 88: ...ldamise teenistuse v i kauplusega kust Te toote ostsite Finnish notice Laitteiden h vitt minen kotitalouksissa Euroopan unionin alueella Jos tuotteessa tai sen pakkauksessa on t m merkki tuotetta ei s...

Страница 89: ...Menschen und die Umwelt sch tzt Informationen dazu wo Sie R cknahmestellen f r Ihre Altger te finden erhalten Sie bei Ihrer Stadtverwaltung den rtlichen M llentsorgungsbetrieben oder im Gesch ft in de...

Страница 90: ...N A embalagem indica que o produto n o deve ser descartado no lixo dom stico comum responsabilidade do cliente descartar o material usado lixo el trico encaminhando o para um ponto de coleta para rec...

Страница 91: ...d Para obtener m s informaci n sobre los puntos de recogida de residuos el ctricos y electr nicos para reciclado p ngase en contacto con su ayuntamiento con el servicio de eliminaci n de residuos dom...

Страница 92: ...aff ren d r du k pte produkten f r att f mer information om var du kan l mna ditt avfall f r tervinning 92 Regulatory compliance and safety...

Страница 93: ...you are properly grounded when touching a static sensitive component or assembly Grounding methods There are several methods for grounding Use one or more of the following methods when handling or in...

Страница 94: ...tical Security Parameter CUP Control unit port An optional feature used to manage and monitor FICON directors D DA Directory agent An iSCSI software component DAS Direct attached storage DCBX Data Cen...

Страница 95: ...ate traffic across ISLs and ensure that each initiator target pair of devices has the required bandwidth for data transfer 2 Federal Communications Commission An independent United States government a...

Страница 96: ...ndent fabrics for B series switches LTU License to use LUN Logical unit number An identification scheme for storage disks LWL 1 Long wave laser 2 Long wavelength M M series Fibre Channel switches manu...

Страница 97: ...n for heterogeneous and virtual tape libraries SMI Storage Management Initiative MIB SNIA Storage Networking Industry Association SOTCP Storage Optimized Transmission Control Protocol SP Service pack...

Страница 98: ...to a Fibre Channel device WWPN Worldwide port name Synonymous with pWWN X XCS Xcelerated Controller Software The software that runs in the HSV controller based Enterprise Virtual Array XL model storag...

Страница 99: ...assembly 68 B battery replacement notice 86 boot 80 C cabling and configuring 37 cabling considerations 26 changing switch name 46 commands configupload 45 fabricshow 45 ipaddrshow 40 licenseadd 20 li...

Страница 100: ...ric 7 8 80 7 8 80 power pack 7 encryption 7 encryption power pack 8 FCoE Converged Network 8 power pack models 8 I Installation plenum 36 installation as standalone device 27 items required for 27 rac...

Страница 101: ...SKM 13 specifications facility requirements 74 Fibre Channel port 79 memory 73 physical 73 POST and boot 80 power supply 75 Subscriber s Choice Hewlett Packard Enterprise 81 supported HBAs 80 supporte...

Отзывы: