Press 

UP

 and 

DOWN

 for setting current time clock or setting time in programming or changing

Selections in configuration menu or setting the time when a temporary hold period will end

(15)

 

Emergency

” flashes when system mode is set “

EMER

” 

“ 

Using Schedule

” displays when thermostat is operating under presetting schedule 

“ 

Permanent Hold

” displays when thermostat is in permanent hold setting temperature period 

 Temporary Hold

” displays when thermostat is in temporary hold setting temperature period 

(16)

displays when first stage cooling activate

displays when both first stage cooling and second stage cooling activate

(17)

displays when first stage heating activate

displays when both first stage heating and second heating activate

(18)

displays when Auxiliary heating or Emergency heating activate

(19)

displays when circulating fan activate

(20)

“TECHNICIAN SET UP: USE UP AND DOWN FOR CURRENT SELECTION AND NEXT STEP

PREVIOUS STEP KEY TO THE NEXT PREVIOUS STEP

” displays to help technician how to

operate in configuration mode

(21)

Indicate current status of the thermostat

(22) “

Chg Filter

” displays indicate changing filter count back has expired

(23) “

Comp Dly

” displays when compressor delay lock out activate

(24) “

Chg UV

” displays when changing UV duration days has expired

HEVAC CONTROL AGENCIES 

7/54 HOWLEYS RD NOTTING HILL 3168 VIC.

Ph. 03 9562788   visit our web site   

www.hevac.com.au

-

12

-

sales 

22

/02/16

Содержание RTC4v

Страница 1: ...Run UNTIL timer Intelligent optimised morning start option Optional Air filter change indicator selectable Optional UV light change indicator selectable APPLICATION The RTC4v room thermostat is ideal...

Страница 2: ...2 KEYBOARD DISPLAY AND SWITCH DESCRIPTION Typical running screen...

Страница 3: ...screw anchors to secure the base 4 Fasten base snugly to wall using mounting holes shown in Figure 3 and two mounting screws Leveling is for appearance only and will not affect thermostat operation 5...

Страница 4: ...for Heat mode I Y Compressor I RC 24v Active for cool RH 24v Active for heat C S1 Neutral G Fan O P W Heat O P Y Cool O P HEAT PUMP UNITS HP2 PROGRAM HEAT COOL APPLICATIONS 2H PROGRAM 1 STAGE RC 24v...

Страница 5: ...or to adjust the minutes or hours Press NEXT STEP to shift between setting minutes and setting hours Press DONE to save exit or press CANCEL to exit without changing the time Adjust program schedules...

Страница 6: ...ETURN time HEAT set point 3 Press the RETURN button and the existing start time and set point will appear alter temp time as required 4 Press the LEAVE button and adjust finish time as required 5 In t...

Страница 7: ...ection for domestic applications Fan set to On causes the fan to run continuously during the RETURN time period as required to meet ventilation standards in commercial applications The fan heating coo...

Страница 8: ...m schedule Whatever temperature you set will be maintained 24 hours a day until you manually change it or press RUN SCHED to cancel Hold and resume the program schedule Vacation Hold Override This fea...

Страница 9: ...way for inquiry for the count back time Inquiry for UV lamp duration time This operation is only available when UV lamp duration time is set Configuration menu item 18 explains the way for inquiry for...

Страница 10: ...l in your own program times and temperatures Keep the following guidelines in mind when planning your program In Heating lower temperatures will save energy In Cooling higher temperatures will save en...

Страница 11: ...n menu item 8 Press HOLD to permanent hold current set point Press CLEAN DISPLAY for entering 30 second count back time for cleaning the display Press PREVIOUS STEP for going back to last configuratio...

Страница 12: ...age cooling activate 17 displays when first stage heating activate displays when both first stage heating and second heating activate 18 displays when Auxiliary heating or Emergency heating activate 1...

Отзывы: