background image

12

SERVICE & MAINTENANCE

SUMMER STORAGE / NON 
USAGE

Please ensure that your stove is left clean and 
moving components are well lubricated for the 
summer months (during periods of prolonged non 
use). If possible store the throat plate outside of the 
stove, check all moveable components, at regular 
intervals, to ensure they are moving freely.

Allow air movement through the stove, by opening 
the air wash and primary air inlet(s) controls to 
about half way open or leave the door ajar. This will 
allow a free flow of air through the appliance thus 
preventing moisture and condensation 
forming inside the stove and chimney. This
preventative maintenance will ensure your stove 
stays in the best condition for the coming winter 
months.

ADJUSTING THE DOOR HINGES

Once the appliance has been under fire for a 
period of time the fire door may appear to have 
moved out of alignment with relation to the door 
aperture or catch. This is quite normal and due to 
the settling of the casting.
The fire door can be re

-

aligned as follows :

x

When the appliance is cold, open the fire door 
so that it is at right angles to the front of the 
stove.

x

Lift the fire door up off its hinges.

x

Gently tap the hinge pins in the direction to 
compensate for the misalignment. (Fig. 11)

x

Re

-

fit the door and check to ensure it now sits 

square to the body; if not repeat the above 
steps.

       If the fire door needs to be raised,               

please follow :

x

When the appliance is cold, open the fire door 
so that it is at right angles to the front of the 
stove.

x

Lift the fire door up off the hinges.

x

Drop one washer on the top and bottom hinge 
pins. Fit the door and check.

Please Note : 
There is no adjustment to the door lock / 
catch assembly. 

FUEL RETAINER

 

A Fuel retainer is supplied with the stove.
Periodically check for any bowing or heat warp   
age to the fuel retainer and replace if necessary.

                         

Fuel retainer

Please Note : 
This operation should only be carried out when 
the appliance is unlit and cold.

Fig. 11. Adjusting The Door Hinges

Содержание BK132

Страница 1: ...PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE Operating Installation Manual BK132 Rev 03 August 2011 Part No AFS1574 Multifuel Stoves AX The AX Multifuel Stove Range British Made AX1M S2 AX2M S2...

Страница 2: ...ing the grate 6 Firebox Liner Panels 7 Final Check 8 OPERATION Air wash control 9 Primary air control 9 Multipurpose operating tool Ash pan 10 MAINTENANCE Cleaning the stove 11 Summer Storage 12 Adjus...

Страница 3: ...AS OPERATED BY HETAS IF IN DOUBT CONTACT HETAS LIMITED TELEPHONE NUMBER 0845 634 5626 www hetas co uk THIS STOVE MUST NOT BE CONNECTED TO A SHARED FLUE SYSTEM TO ALL USERS PETROLEUM COKE SOME OF WHOSE...

Страница 4: ...andling the fire x Always grip with the palms of your hands do not use your fingertips for support x Always keep the stove as close to the body as possible as this will minimise the cantilever action...

Страница 5: ...Room Heater Only Output kW 1 4 1 5 Height mm A 458 475 Width mm B 330 370 Depth mm C 323 333 Height to Centre of Rear Flue mm D 370 387 Depth from Back to Centre of Flue mm E 93 5 93 5 Flue Diameter...

Страница 6: ...s below on grate assembly Grate The grates in the AX1 2 stoves comprise of a series of 5 cast iron grate bars seated on a pair of combs All bars in the grate are identical the bar is fitted with the e...

Страница 7: ...ide liner panels See Fig 2 x Fit the throat plate with the projecting lugs sitting on top of the side liners The long centre tab on the back edge rests on the rear liner The shorter turn down tabs aga...

Страница 8: ...ocal building control department FINAL CHECK Note All local regulation including those referring to National and European standards need to be complied with when installing the appliance We strongly a...

Страница 9: ...a single control knob which slides left to right Sliding the knob to the Right see Fig 6 will increase the amount of air intake to the stove To Decrease push the slider to the Left as in Fig 7 AIR WAS...

Страница 10: ...the fire door Fig 10a Operating Tool Ash pan 10 OPERATING INSTRUCTIONS Please Note A stove mitten is supplied with your AX stove Fig 10b this is provided for the operation of the fire door handle and...

Страница 11: ...season It is important that the flue ways flue pipe and chimney be cleaned prior to lighting the appliance after a prolonged shut down period DOOR GLASS The door glass should remain clear during norma...

Страница 12: ...door aperture or catch This is quite normal and due to the settling of the casting The fire door can be re aligned as follows x When the appliance is cold open the fire door so that it is at right ang...

Страница 13: ...13 SERVICE MAINTENANCE AX1 Spare Parts...

Страница 14: ...14 SERVICE MAINTENANCE AX2 Spare Parts...

Страница 15: ...ommence on the date of purchase and are non transferable Our guarantee is offered as an addition to your statutory rights The guarantee is applicable to the original purchaser only and is non transfer...

Страница 16: ...Bars Flue Outlet Hot Plate Fuel Retainer Firebox Liners Throat Plate Air Wash Ash Pan Operating Tool Stove Mitten Operating Installation Manual Assembled By Checked By Arada Ltd The Fire Works Weycro...

Отзывы: