6

combustion
air

9

Do not place flammable objects like drying racks, 
furniture, curtains too close to the stove.

1.9 Draft conditions     

 

         

      and the chimney

Poor draft will not allow the stove to burn, as it 
should. The glass can soot, requires cleaning of 
the chimney more often, smoke can escape out 
when the door is open and it gives poor fuel ef-
ficiency. Leading to unnecessary polluting of the 
environment.
Good  draft  will  allow  the  stove  to  achieve  op-
timal  combustion  and  the  highest  possible  ef-

ficiency. Heta wood stoves are constructed so 
that it itself provides an optimal blend of com-
bustion air. This provides a high efficiency/heat, 
clean glass and low environmental impact.
Minimum chimney draft: 12 pascal. 
It is the draft that the stove has been tested and 
approved on. The minimum draft is necessary to 
provide  clean  burning,  beautiful  flame  picture, 
as well as achieving the rated efficiency.
There is a risk of smoke escaping into the room 
if the door is opened during vigorous firing, or if 
there is a lack of air supply to the room, for ex. if 
an extraction fan is in use. 
Ambition 5: 200°C, relative to 20°C. Ambition 8: 
250°C relative to 20°C.
Flue gas flow is:

 

Ambition 5: 4,5 g/sek. Ambition 

8: 5,9 g/sek. Corresponding to 17 m

3

/hr of com-

bustion air by burning 1,2 kg of wood.

The  chimney  height  and  diameter,  as  well  as 
the temperature difference between the flue gas 
and outside temperature generates the chimney 
draft. Chimney insulation is therefore important 
as new efficient stoves create lower flue tempe-
ratures.  Wind  and  weather  conditions  also  in-
fluence  draft,  in  some  cases  it  may  be  disad-
vantageous  wind  direction,  combined  with  the 
position of the chimney can cause negative draft 
(it blows through the chimney), causing smoke 
escape from the stove.
Before  using  after  a  long  period  of  inactivity, 
check that the chimney is free for any blocka-
ges. (soot build-up, bird nests, leaves etc.).

reduced draft can occur when:

• The temperature difference is too small 
   between smoke gasses and outdoor 
   temperature, for eg. poorly insulated chimney
• To short of a chimney
• The outside temperature is high, and indoor    
   temperature is low for eg. in summer
• False air in the chimney
• Chimney is blocked
• Air tight house (lack of combustion air supply)
• Poorly placed chimney for the surroundings,   
   for ex. the ridge and trees may cause 
   turbulence

Good draft occurs when:

• The difference in temperature in the chimney  
   (warmer) and outside temperature (colder) 
• It is clear weather
• The chimney has the right height min 4 meters
   above the stove, and clear of the roof ridge.

1.10 fuel

Your  new  stove  is  EN  approved  for  firing  with 
wood fuel. You must therefore only burn clean, 
dry  wood  in  your  stove.  Never  use  your  stove 
to burn driftwood, as this may contain a lot of 
salt which can damage both the stove and the 
chimney. Similarly, you must not fire your stove
with refuse, painted wood, pressure-impregna-
ted wood or chipboard, as these materials can 
emit poisonous fumes and smoke. 
Correct  firing  using  well  seasoned  wood  pro-
vides  optimal  heat  output  and  maximum  effi-
ciency. At the same time, correct firing prevents 
environmental  damage  in  the  form  of  smoke 
emissions and reduces the risk of chimney fires. 

Содержание Ambition 5

Страница 1: ...1 oPeratinG anD installation instrUCtions Danish design Danish Quality Danish Production www heta dk EN AMBITION Stove is exemt for use in smoke control areas when burning dry wood Pending...

Страница 2: ...883 62 mgC Nm3 ved 13 O2 Fire safety Reaction to fire A1 Test of fire safety in connection with the burning of wood Approved Distance to combustible materials Rear whit insulation whitout insulation S...

Страница 3: ...883 92 mgC Nm3 ved 13 O2 Fire safety Reaction to fire A1 Test of fire safety in connection with the burning of wood Approved Distance to combustible materials Rear whit insulation whitout insulation S...

Страница 4: ...imum fuel economy The Ambitions are recommended as exempt for use within smoke control areas SCA throughout the UK see clean air act Appendix A of the air supply regulation so that it can t be closed...

Страница 5: ...dealers Neverthe less when in transport or handling damage of the often heavy stoves can occur It is important that upon receipt check your Heta product completely and report any damage or defects to...

Страница 6: ...art materiale bag ovn Afstand l br ndbart materiale side af ovn Afstand l m bel Middel CO emission nominel last ved 13 O2 Middel CO emission I Mg Nm3 ved 13 O2 656 Mg R ggas Temp Nominel last 261 C St...

Страница 7: ...n 5 and 42 for Ambition 8 of its fully open position A permanent amount of air will therefore enter the firebox to feed the fire producing negligible amounts of smoke and unburnt hydrocarbons The appl...

Страница 8: ...eft for a long time Never empty ash into a combustible container 1 7 Reduced burning The stove is approved for intermittent use Never turn down the air down so much that there does not come any flames...

Страница 9: ...create lower flue tempe ratures Wind and weather conditions also in fluence draft in some cases it may be disad vantageous wind direction combined with the position of the chimney can cause negative d...

Страница 10: ...NACS natio nal association of chimney sweeps registered chimney sweep In the event of smoke or malodorous fumes are being produced you must first check to see whether the chimney is blocked The chimne...

Страница 11: ...on chamber is visible Too rapid combustion Too much chimney draft To test you can open the cleaning hatch but remember to close it again Measure the chimney draft and install a damper in the flue pipe...

Страница 12: ...C VI C Cleaning combustion air intake C C Cleaning of the firebox C VI C Checking switch gasket for door C S VI C S Checking changing gasket for glass C S VI C S Checking changing gasket for flue pipe...

Страница 13: ...17 Cleaning after sweeping or before replacing vermiculite stones Note it may be necessary to clean vaccum the holes and air ducts behind the rear stone Order of removing Fire bricks Replace in revers...

Страница 14: ...08 9086 Hinge pin 6x40 SS 2 6 0016 0031 Handle 1 7 1013 0732 Door hock 1 8 0008 1007 Flat screw M6x6 4 9 0008 0040 M5x10 Ch 2 10 0008 9015 Pin 5x26 1 11 0008 3503 Brass disc M6 6 4 11 1 6 1 12 1013 07...

Страница 15: ...2 Back stone top right 1 8 0023 004879 Back stone bottom right 1 Ambition 5 Parts Inside fire chamber Ambition 8 Parts Inside fire chamber 6 5 2 1 3 7 8 4 Pos No Name Qty 1 0023 005003 Back stone top...

Страница 16: ...tallation Instructions Contents 2 Installation instructions 17 2 1 Distance requirements 17 2 2 Floor 17 2 3 Chimney connection 17 2 4 Combustion air and ventilation 18 2 5 Stovedrawings measurments 1...

Страница 17: ...ront of the fireplace stove the substrate must consist of non combustible material for ex Steel glass plate stone or tile floor The size of the non combustible surface must follow the applicable natio...

Страница 18: ...ir inlet vent The air inlet vent must be fitted correctly and insulated to prevent formation of condensate The cross section of the vent and grille must be at least 78 cm If the vent leads out into th...

Страница 19: ...19 345 100 125 137 345 920 381 920 550 458 817 Ambition 5 Ambition 8 416 100 125 mm 138 454 416 619 619 550 516 156...

Страница 20: ...nnecting direct air behind When installing external air supply connect the air intake to the direct air pipe using flexi pipe Flexi pipe not included Ambition 8 416 457 817 550 920 125 135 454 416 920...

Страница 21: ...mensions in mm Distance to flamable materials A rear the stove with insulation without insulation B at the sides C over the stove D to furniture Ambition 5 150 200 400 385 1100 Ambition 8 175 225 400...

Страница 22: ...22 2 8 Changing to back outlet 2 3 5 4 6 DETAIL D SCALE 1 1 5 1 4025 0007 1500 001146...

Страница 23: ...the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area It is an of fence to emit smoke from a chimney of a buil ding from a furna...

Страница 24: ...24...

Отзывы: